Communications Mode
7.3.1
Setting the CP 523 Parameters with the Memory Submodule
You can store the parameter setting data on a memory submodule in data block (DB) 1.
Note:
The procedure for setting the memory submodule parameters in Communications mode is
almost identical to the procedure in Print mode. The only difference is in configuring parameter
block 7, in which additional data must be specified in Communications mode.
Entering the parameter blocks
First, you must enter all the parameter blocks to be changed in DB 1 on the programmer. Then
transfer DB 1 to the memory submodule.
Further tips for input:
To make the programmer screen presentation clearer, alternate between the "KC" and "C"
formats.
You can enter comments in addition to the parameter blocks.
Schematic for entering parameter blocks
The parameter blocks can be entered in DB 1 according to the following schematic:
Block separator
":" (3A
Figure 7-5. Schematic for Entering Parameter Blocks in DB 1
The following pages contain the parameter block assignments and an example for entering
parameter setting data with the PG 685.
Note:
Parameter block assignment for setting parameters with the memory submodule corresponds to
the assignment of bytes 2 to 7 of the transfer memory when setting parameters with the user
program.
7-10
Parameter block
)
H
Configuration
no.
CP 523
data
EWA 4NEB 811 6044-02a