Siemens SIMATIC S5 CP 523 Manual page 141

Serial i/o module
Hide thumbs Also See for SIMATIC S5 CP 523:
Table of Contents

Advertisement

Communications Mode
Transferring parameter setting data for parameter block 7
Table 7-17. Transfer Memory Assignments for "Transfer Parameter Setting Data
Byte
0
Job number
"Transfer parameter setting"
1
Bits 4 to 7: Parameter block number
Bits 0 to 3: Mode
2+3
Character delay time
(1 to 3000) · 10 ms
4+5
Message frame length (1 to 256 bytes)
One (Byte 7) or two (bytes 6 and 7) end-
of-text characters must be specified if
message frame length is 0 bytes
6+7
End-of-text characters
(only when message frame length= 0)
1 end-of-text character (Byte 6=0)
2 end-of-text characters
* Possible in Interpretive mode only
7-36
for Parameter Block 7"
Description
Print mode
Transparent mode
Interpretive mode
"3964(R)" mode
*
Possible Values
90
H
7
0: when memory
0
1
2
3
1: no memory subm.
0001
to 0BB8
H
H
0000
H
0001
to 00FF
H
H
0101
to FFFF
H
H
CP 523
Default Values
on the CP 523
-
-
submodule with
message texts is
plugged in
0001
6 10 ms
H
0040
H
No end-of-text
character
EWA 4NEB 811 6044-02a