VI. f - CONTROL FEATURE -
ON DEMAND DEFROST:
Proper attention should be given to defrosting
your unit. Every "event" or time the unit is used
with the door open, the coil will build-up ice. This
reduces the effectiveness of the overall operation
of the unit. To prevent the build-up of ice on the
coil, Traulsen has included an "On-Demand"
defrost feature. To initiate an on-demand defrost,
simply press the ON-DEMAND DEFROST button.
Use this feature once a day or as needed to
achieve proper performance.
VI. g - CONTROL FEATURE -
2-STAGE THERMOSTAT:
A 2-Stage thermostat is provided standard with all
Air Curtain units manufactured with an electronic
controller (see section VI. a).
This allows the user to choose from two
operating modes:
1) Standard Operating Mode of 36°F, or
2) Lo-Temp Operating Mode of 34°F.
VI. ELECTRONIC CONTROLLER (continued)
TEMP RECALL
Press To Display Either
Actual or Set-Point Temperature
ON/OFF
Serves Two Functions, Turns
Cabinet ON or OFF And Also
Allows You To Change The
Temperature Scale From
Degrees (F) Fahrenheit To
Degrees (C) Celsius As Required.
Lo-Temp Operating Mode provides you with
the added flexibility of being able to pre-chill
products (such as milk and juices) for prolonged
"Tray Delivery" times.
VI. h - GENERAL OPERATING INSTRUCTIONS:
1) Pre-chill cabinet with door closed for minimum
of 1 hour with empty trays in position stabilize
at 36°F (2.2°C) or desired set temperature.
2) Load cabinet from bottom to top, PUSH TRAYS
TO REAR OF WALL.
3) After loading, close cabinet door and allow
inside temperature to re-stabilize to desired
temperature.
4) Unload cabinet from top to bottom.
Keep empty trays in position.
5) This unit is equipped with an automatic
condensate evaporator. To prevent water spills,
turn unit OFF and leave unit plugged in with
door closed. Temperature will elevate during
defrost cycle.
-5-
STANDARD TEMP operating
temperature is pre-set at 36°F (2.2°C)
with temperature range 32°F to 40°F
(0°C to 4.4°C).
COLDER TEMP operating
temperature pre-set at 34°F (1.1°C)
with temperature range 25°F to 35°F
(-4°C to 1.6°C).
TO SELECT STAGE:
Press and hold STANDARD TEMP
(Arrow UP) or COLDER TEMP
(Arrow DOWN) for 5 seconds.
TO CHANGE TEMPERATURE:
Press UP Arrow or DOWN Arrow.
ON DEMAND DEFROST
Press To Initiate On-Demand
Defrost - OR - over-ride a defrost
cycle in progress