SP8-XXX (Data Log 2)

The counters in Data Log 2 are commonly used in multiple machines. Data Log 2 includes
the counters of the functions or units that are not supported by Model G-P1a and P1b. The
counters in Data Log 2 are cleared by SP5-801 (Memory Clear) or SP7-808 (Counter
Reset).
Keys and abbreviations in Data Log 2
Program-related keys and abbreviations
T:
The grand total of the counters of all application programs
The counter of the printer application program excluding the events related
P:
to the document server
The counter of other application programs including remote application
O:
programs
8001
[T: Total Jobs]
8004
[P: Total Jobs]
The number of times the application program starts a job
[0 to 9999999/ 0 / 1]
The jobs interrupted by paper jams or some other errors are also counted.
The jobs executed by SPs are not counted.
8021
[T: Pjob/LS]
8024
[P: Pjob/LS]
8027
[O: Pjob/LS]
The number of times the application program stores data on the document
server
[0 to 9999999/ 0 / 1]
SM
*CTL
Total jobs
*CTL
*CTL
Print job
*CTL
/ Local storage; document server