GE NX-4-EUR Installation Manual page 78

Networx series
Table of Contents

Advertisement

37
46
1
dial via GSM when phone line trouble (only when NX-7002 is used)
2
Exit Error limited to Entry/Exit delay 1
1-8
Reserved
38
47
SWINGER COUNTDOWN COUNT
39
47
KEYPAD SOUNDER CONTROL
1
Keypad sounds for Telephone Line Cut when in the Armed state
2
Keypad sounds for Telephone Line Cut when in the Disarmed state
3
Keypad sounds upon AC Power Failure
4
Keypad sounds upon Low Battery Detection
5
Keypad sounds during Cross Zone Trip Time
6
Keypad sounds for Tamper Alarm
7
Keypad sounds for Emergency keys
8
Keypad sounds for Expander Trouble
40
48
SYSTEM TIMERS
Segment 1
Segment 2
Segment 3
Segment 4
Segment 5
Segment 6
Segment 7
Segment 8
Segment 9
Segment 10
Segment 11
Segment 12
Segment 13
Segment 14
41
48
USER CODE REQUIREMENTS
1
Enables six digit code option. All arm/disarm/Go to program codes require six digits
2
Requires valid user code entry so that [*]-[9]-[8] and [*]-[9]-[9] functions can work
3
Enables Auto Cancel / Abort
4
Reserved
5
On: keypad shutdown mode
6
On: user authorization to enter program mode
7
Reserved
8
Reserved
NX-4-EUR Installation manual
Segment 7 (Circle Numbers To Program)
Segment 1 (Circle Numbers To Program)
Dynamic Battery Test duration (0-255 minutes)
AC Failure report delay (0-255 minutes)
Power Up Delay (0-60 seconds)
Siren Time (1-255 minutes)
Telephone Line Cut delay (0-255 seconds)
Cross Zone Time (0-255 minutes)
Chime Time in 50 mS increments (0-255)
Dialer delay (0-255 seconds)
Fire Alarm Verification Time (120-255 seconds)
Listen-In Time (0-255 seconds)
Zone monitor timer hours/days (0-255)
Auto arming warning timer (1-255 minutes)
Auto arming retry timer (1-255 minutes)
Programming timeout (1-255 minutes) ("0"=15 minutes)
Segment 1 (Circle Numbers To Program)
Page 78
0
0
60
0
3
0
5
5
0
0
0
0
1
45
0
02/07/06