CHANGING USER CODES
1.
2.
3.
4.
5.
6.
[*]-[6]
ASSIGNING AUTHORITY LEVEL
1.
2.
LED
1
2
3
4
5
6
7
8
1.
2.
NX-4-EUR Installation manual
Enter [*]-[5]-[master code]- the "Ready" LED will flash.
Enter the 2 digit user number (always 2 digits, such as "03" for user 3)- the "Ready" LED
will illuminate steadily.
Enter the new user code designated for the person in question - the "Ready" LED will
flash, indicating that the code has been accepted. If the code is rejected, the sounder will
beep 3 times.
If another user code needs to be programmed, return to step 2.
Press [#] while the "Ready" LED is flashing in order to exit the user code programming
mode.
Pressing four times (for 4-digit code) can erase a user code or six times (for 6-digit code)
the "Cancel" key.
Enter [*]-[6]-[master code]- the "Ready" LED will flash.
Enter [2 digit user number] (always 2 digits, such as 03 for user 3)- the "Ready" LED will
illuminate steadily and the "Instant" LED will flash. Refer to the chart below for the
description of each LED. Turn on the LED for the features that you want.
ATTRIBUTES IF LED 8 IS OFF
Reserved
Arm only
Arm only after closing window
Master arm/disarm (can program
other codes)
Arm/disarm code
Allowed to bypass zones (see location
23)
Code will send open / close reports
If this LED is on, LED's 1-7 will use the
chart too the right
Enter [*]: The "Instant" LED will illuminate steadily.
This moves you to the 'partition enable'. (This tells the system which partition this user
can arm/disarm.) LED's 1-8 will light up for each partition that the user is authorised to
arm/disarm. To change any of these numbers, press 1-8 to permit or deny access to the
user. (Example: If LED 2 is lit, then the user has been assigned access to that partition. By
pressing the [2] key, the LED will go out, indicating the user has been denied access to
that partition.)
Enter [*]:
This brings you back to step 2 above. At this point, you may enter another user number to
which you can assign attributes. You may continue this procedure until you have
assigned authority levels to all user numbers; otherwise, you may press the [#] key to exit
the assigning authority level program.
Page 16
LED
ATTRIBUTES IF LED 8 IS ON
1
Activate output 1
2
Activate output 2
3
Activate output 3
4
Activate output 4
5
Arm/disarm code
6
Allowed to bypass zones (see location
23)
7
Code will send open / close reports
8
If this LED is off, LED's 1-7 will use the
chart on the left