Telephone number 2

LOCATION 6 - PROGRAMMING PHONE N° 2 (20 segments, numerical data)
Phone N°2 is programmed in location 6. A "14" indicates the end of the phone number. Delays
of four seconds can be programmed at any point in the phone number by programming a
"13" in the appropriate segment. The system will always wait for a dial tone unless the first
digit of the phone number is a "13"; in this case, it will only delay. Tone (DTMF) dialling is
default. If you want pulse tone dialling, program a "15" in the segment where pulse dialling
should begin. If the entire number should be pulse dialling, program a "15" in the first segment.
Program an "11" for a "*", and a "12" for a "#".
Note: a zero is programmed as a "0".
LOCATION 7 - ACCOUNT CODE FOR PHONE N° 2 (6 segments of numerical data)
Use location 7 to program the account code that is sent when phone N°2 is dialled. A zero in
the account code is programmed as a "0". A "10" indicates the end of the account code, so
program a "10" in the segment immediately after the last digit of the account code. If the
account code is 6 digits long, program all 6 segments. If this location is left unprogrammed,
account code 1 will be used when the second phone number is dialled.
LOCATION 8 - COMMUNICATOR FORMAT FOR PHONE N° 2 (1 segment, numerical data)
Location 8 contains the communicator format used to transmit to the receiver that is
connected to phone N°2. Consult the instruction manual for your central station receiver in
order to determine which format is compatible, and select from the 15 formats listed on page
33. If you require a format other than those listed, review the override options described in
Location 18 to create the appropriate format. In order to create a special format, a "15" must
be programmed in location 8, in addition to the entries in location 18. If this location contains
a "0", format 1 will be used when phone N°2 is dialled.
LOCATION 9 - DIAL ATTEMPTS/BACKUP CONTROL FOR PHONE N° 2 (2 segments, numerical data)
Segment 1, dial attempts: segment 1 of location 9 is used to enter the number of dial
attempts (1 to 15 attempts) that the communicator will make to phone N°2 before it ends the
notification process. Factory default is "0", and the communicator will make the same number
of attempts as those programmed in location 3.
There will be a waiting time of 12 seconds between the first two dial attempts, and a
waiting time of 60 seconds between each subsequent dial attempt (regardless of the
number dialled).
Segment 2, phone N° 2 backup control: Programming a "0" in segment 2 of this location will
cause the NX-4 to make the designated number of attempts to phone N°1 before setting the
"fail to communicate" condition and stop reporting. Programming a "1" in this segment will
cause the NX-4 to stop trying to communicate after the designated number of attempts have
been made to phone N°2. If a "2" is programmed in this segment, it will cause the NX-4 to
make the dial attempts in increments of two. The first two attempts will be made to phone
N°2, the next two attempts to phone N°1, then repeating until the total number of attempts
designated in segment 1 is completed.