Important Remarks; Tamper Memorization; Disabling Tamper Alarms In Program Mode; Country Code - GE NX-4-EUR Installation Manual

Networx series
Table of Contents

Advertisement

Tamper memorization

If location 37 segment 6 option 8 is set, tamper alarm indications (zone tampers and box
tampers) can be erased by entering a valid user code.
If location 37 segment 6 option 8 is not set, tamper alarm indications (zone tampers and box
tampers) can only be erased by entering the program mode. In this case, tamper alarm
indications can only be reset by the installer.

Disabling tamper alarms in program mode

Tamper alarms (originating from zones and boxes) will be disabled during program mode. This
allows the installer to service the system without generating unwanted tamper alarms. Note
that the timeout for the program mode is 15 minutes.

Country code

The NX-4 has the ability to set different "country codes". Each country code has specific
default settings. Before start programming the NX-4, it is important to select the country code
that is required. Once the country code has been selected, it will remain set, even after an
installer reset. When changing the country code during programming, all existing
programming will be cleared to the defaults for that country (see location 213).

Keypad tamper lockout

When this option is enabled (see location 23, segment 1), the NX-4 will disable the keypad for
60 seconds, and will communicate a tamper signal to the central station if 30 key presses are
entered without producing a valid code.
NX-4-EUR Installation manual
I
MPORTANT REMARKS
Page 33
02/07/06

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents