Circular Vial - Pentax R-315EX(NX) Instruction Manual

R-300x series basic
Table of Contents

Advertisement

[Adjustments]
It is necessary to adjust as following when the bubble is not in the vicinity of the center in
the confirmation of
[Procedure to adjust the electronic vial]
Press the [POWER] and [LASER] key simultaneously.
Following screen is viewed.
Aim at a target and press [F3] key.
Following screen is viewed.
Turn the instrument 180° and reverse the
telescope. Aim at the same target accurately,
then press [F3].
Following screen is viewed.
Pressing the [ENT] key completes the adjustment.

10.2 Circular vial

[Checks]
Adjust by the electronic vial beforehand.
1
Confirm the position of the bubble of the circular vial.
2
At this time, it is not necessary to adjust if the bubble is at the center of the circle.
[Adjustments]
When the bubble of the circular vial comes off from the center according to check
procedure
2
Turn the bubble adjustment screw with a hex wrench (L type wrench) and put the bubble
in the center of the circle.
[Only the detaching type model]
Turn the bubble adjustment screws with the reticle adjustment pin and put the bubble in
the center of the circle.
60
.
4
, it is necessary to adjust.
Electronic vial adj.
Avoid direct sunlight and viration
during adjustment. Aim at a target
accurately, then press [F3]
0 SET
F3
Electronic vial adj.
Turn the instrument 180° and reverse
the telescope.
Aim at the same target accurately,
the, press [F3]
0 SET
F3
Electronic vial adj.
Successfully accomplished.
Press [ENT]
F5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents