Paxar Monarch 9412 Reference Manual page 61

Paxar printer packet reference manual
Table of Contents

Advertisement

When you copy this field into another field, the maximum number
of characters for the final field is 2710 (or 0-100 for 9403). Allow
only as many characters as you need, because extra characters
use up space. Also, if you are copying into a bar code field, the
maximum number of characters in the destination bar code is
determined by the bar code specification (UPCA-12, EAN-13,
etc.). You need to apply field options to manipulate the text
entered in this field. For example, you may want to copy data
from this field into another field. See "Option 4 Copy Data" in
Chapter 5 for more information.
In the following example, data is entered into four non-printable
fields and merged to form field 5, and is then printed as a bar
code. See "Merging Fields" in Chapter 5 for more information.
Field
Data
1
20374
2
339
3
8
4
15
5
20374339815
Each non-printable text field requires a separate definition.
Syntax
D1. D
Non-Printable Text Field.
D2. field#
Unique number from 0-999 assigned to this field.
Maximum number of characters in this field: 0-2710.
Defines a non-printable text field (field #4) with a maximum of 20
characters.
Field Type
Non-printable
Non-printable
Non-printable
Non-printable
Bar Code
D,field#,# of char
D,4,20
Defining Fields 4-13