Paxar Monarch 9412 Reference Manual page 109

Paxar printer packet reference manual
Table of Contents

Advertisement

Status2
C- Field Number
Status2
D- Parameter
Status2
E- Error Number
"FMT-1/BCH-2"
If more than one error occurred then only the
most serious error will be acknowledged.
{J,"","F,B,4,6,33","FMT-1","BCH-2"}
Indicates that an error occurred on a bar code (B) field within a
format (F) packet. The bar code field is the fourth (4) field in the
packet. The error occurred in the sixth (6) parameter of the field.
Error number 33 means the bar code density is invalid.
To clear an error, press the FEED button. An ENQ can also clear
errors numbered less than 500. Once the error is corrected, a job
request can be sent. The printer cannot accept another job
request until the error is resolved.
represents the field number within each
packet. The packet header is the first field
and each subsequent field is indicated by the
field separator.
represents the parameter within the field that
the error occurred. The numbering begins
after the field identifier.
is the error that coincides with the error
numbers presented in Chapter 9, "Errors."
The format or batch number is returned.
Status Polling 7-11