Paradyne IP Broadband Loop Carrier 12000E Installation Instructions Manual page 13

Ip broadband loop carrier
Hide thumbs Also See for IP Broadband Loop Carrier 12000E:
Table of Contents

Advertisement

IPD1-A2-GZ40-10
4. Using a Phillips screwdriver, remove the left-hand screw from the chosen
terminal block (labeled "+" on the chassis). Slide the ring terminal of your
positive power lead around the shaft of the screw and insert the screw into the
same "+" terminal from which it was removed.
Positive (+) Terminal
DC POWER TERMINAL
5. Remove the right-hand screw (labeled "–") from the same terminal block. Slide
the ring terminal of your NEGATIVE lead around the shaft of the screw and
re-insert the screw into the same "–" terminal from which it was removed.
Negative (–) Terminal
DC POWER TERMINAL
CAUTION:
Observe proper polarity.
6. Connect both power leads to a fuse panel. The negative (–) lead connects to a
"Batt" (Battery) terminal and the positive (+) lead connects to a "Return"
terminal on your DC power supply.
July 2005
POSITIVE POWER LEAD
Ring Terminal
NEGATIVE POWER LEAD
Ring Terminal
13

Advertisement

Table of Contents
loading

Table of Contents