Advertisement

Quick Links

All manuals and user guides at all-guides.com
BitStorm
2600
IP DSLAM
Installation Guide
Document No. 2600-A2-GN20-10
January 2004

Advertisement

Table of Contents
loading

Summary of Contents for Paradyne BitStorm 2600

  • Page 1 All manuals and user guides at all-guides.com BitStorm ™ 2600 IP DSLAM Installation Guide Document No. 2600-A2-GN20-10 January 2004...
  • Page 2 Paradyne worldwide office locations, use one of the following methods: Internet: Visit the Paradyne World Wide Web site at www.paradyne.com. (Be sure to register your warranty at www.paradyne.com/warranty.) Telephone: Call our automated system to receive current information by fax or to speak with a company representative.
  • Page 3 All manuals and user guides at all-guides.com Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. This product is intended to be used with a 3-wire grounding type plug — a plug that has a grounding pin. This is a safety feature.
  • Page 4 CE Marking When the product is marked with the CE mark on the equipment label, a supporting Declaration of Conformity may be downloaded from the Paradyne World Wide Web site at www.paradyne.com. Select Library → Technical Manuals → CE Declarations of Conformity.
  • Page 5 All manuals and user guides at all-guides.com Japan Class A ITE This is a Class A product based on the standard of the Voluntary Control Council for interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.
  • Page 6 All manuals and user guides at all-guides.com January 2004 2600-A2-GN20-10...
  • Page 7: Table Of Contents

    Installing the BitStorm 2600 Into a Rack ..... . . „ Installing the BitStorm 2600 on a Wall ......1-10 „...
  • Page 8 „ BitStorm 2600 Startup Procedure ......Login ..........
  • Page 9: About This Guide

    All manuals and user guides at all-guides.com About This Guide Document Purpose and Intended Audience This document is written for technicians who install the BitStorm 2600 IP DSLAM. Document Summary Section Description Chapter 1, Installation Describes the physical installation of the BitStorm 2600 into a rack.
  • Page 10: Related Product Documents

    BitStorm 6051 POTS Splitter Installation Instructions 6381-A2-GN10 Hotwire ADSL/R Bridge/Router, Model 6381, with Inline Phone Filter, Installation Instructions 7890-A2-GB22 GrandVIEW EMS User’s Guide To order a paper copy of a Paradyne document, or to talk to a sales representative, please call 727-530-2000. January 2004 2600-A2-GN20-10...
  • Page 11: Installation

    Paradyne GrandVIEW™ Element Management System (EMS). Up to eight BitStorm 2600 units can be logically stacked, with aggregation for up to 192 ports of DSL traffic. Both ReachDSL and ADSL units can be included in the same stack.
  • Page 12: Preparation

    Up to five BitStorm 2600 units may be stacked on a shelf or desktop. Different models can be mixed in a stack. „ Power The BitStorm 2600 operates from a 90 to 265 VAC, 47 to 63 Hz power source. „ Other Cabling No cables are provided with the BitStorm 2600. See...
  • Page 13: Cables Required

    (UTP) Network (LAN) employing cable. 10BaseT or 100BaseT. CONSOLE DB9 plug connector and The BitStorm 2600 to one of the shielded cable. following: The other connector A terminal or a PC with a depends on the serial port on...
  • Page 14: Unpacking The Hardware

    The BitStorm 2600 is shipped in a cardboard shipping container. Carefully remove the unit from its shipping container and check for physical damage. If the unit shows signs of shipping damage, notify your sales representative.
  • Page 15 All manuals and user guides at all-guides.com 1. Installation Table 1-3. Contents of Hardware Kit Shipped with the BitStorm 2600 Appearance Description Quantity Flat-head screw for attaching 19" mounting brackets to unit 02-17259 Machine screw with captive starwasher (6-32 x 1/4″) for attaching 23"...
  • Page 16: Mounting Configurations

    1-12. Mounting Brackets Your BitStorm 2600 can be installed in a rack or on the wall using mounting brackets. Two brackets suitable for a 19-inch (483 mm) rack (marked EIA-19) and two brackets suitable for a 23-inch (584 mm) Bay Networks or Nortel rack (marked with Paradyne Part Number 868-6282-0020) are shipped with the unit.
  • Page 17 All manuals and user guides at all-guides.com 1. Installation 3. Identify six flat-head screws (for 19-inch racks) or six machine screws (for 23-inch racks) provided with the mounting brackets in the hardware kit. 4. Attach the brackets appropriate to your rack size. Tighten all screws firmly. 19-inch (483 mm) Rack Mount 23-inch (584 mm) EIA and Bay Networks Rack Mount...
  • Page 18: Installing The Bitstorm 2600 Into A Rack

    Procedure To install the BitStorm 2600 into a rack: 1. Determine where in the rack you will mount the BitStorm 2600. If your rack does not have threaded screw holes, slip self-retaining nuts onto the rails where the BitStorm 2600 will be fastened.
  • Page 19 All manuals and user guides at all-guides.com 1. Installation 3. Insert and tighten the screws in the top screw positions, then tighten the bottom screws. 03-17436 2600-A2-GN20-10 January 2004...
  • Page 20: Installing The Bitstorm 2600 On A Wall

    3/4-inch (19 mm) plywood (not drywall). Procedure To install the BitStorm 2600 on a wall: 1. Identify the flat-head screws provided in the hardware kit and the brackets suitable for a 19-inch rack. Two screws are required for each bracket.
  • Page 21 All manuals and user guides at all-guides.com 1. Installation 6. Install two wood screws (not provided) at the same height above the floor and 18.75 inches (476.25 mm) apart. Do not completely tighten the screws. Leave them so their heads are about 1/4 inch (6 mm) from the wall. 17.85 in (453 mm) 03-17437 7.
  • Page 22: Installing The Bitstorm 2600 On A Shelf Or Desktop

    Procedure To install the BitStorm 2600 on a shelf or desktop, as a standalone unit or in a stack: 1. Locate the rubber feet in the hardware kit provided with the unit.
  • Page 23: Cabling

    All manuals and user guides at all-guides.com Cabling Cabling Overview The BitStorm 2600 has a large variety of possible cabling configurations. This chapter describes all possible connections, not all of which are required: „ DSL Ports on page 2-2 „...
  • Page 24: Dsl Ports

    All manuals and user guides at all-guides.com 2. Cabling DSL Ports The BitStorm 2600 DSL connector supports the tip and ring connections of up to 24 DSL ports over a 50-position cable. A POTS (plain old telephone service) splitter connector is also provided, for CO applications only.
  • Page 25: Gige Uplink (Port 3)

    Paradyne. See Appendix B, Equipment List. Either interface can be used as the uplink for a single BitStorm 2600, or for the terminating unit in a stack of BitStorm 2600s. Procedure To use Port 3 as the uplink: 1.
  • Page 26: 10/100Baset Uplink (Port 2)

    10/100BaseT Uplink (Port 2) Port 2 can be configured as the uplink for a single BitStorm 2600, or for the terminating unit in a stack of BitStorm 2600s. A straight-through cable can be used regardless of the destination interface, since the port automatically distinguishes between an MDI and an MDIX.
  • Page 27: Chaining Bitstorm 2600S

    All manuals and user guides at all-guides.com 2. Cabling Chaining BitStorm 2600s Up to eight BitStorm 2600s can be chained together to use a single uplink. The same port (eth2 or eth3) used as the uplink for one unit must be used as the downlink for the next.
  • Page 28: Management Port

    1. Connect an 8-position modular cable to Port 1. 2. If the BitStorm 2600 is in a rack, fasten the cable to a rail with a cable tie. 3. Connect the other end of the cable to your Ethernet hub or to a network interface card in a PC.
  • Page 29: Console Port

    The CONSOLE port normally serves as the primary user interface with the BitStorm 2600 during installation. You can connect a terminal or PC directly to the CONSOLE port using a DTE cable (see procedure below). You can also use the...
  • Page 30: Connecting A Modem To The Console Port

    3. If the modem will be permanently connected, fasten the connector to the Management Module with its captive screws. If the BitStorm 2600 is in a rack, dress the cable to the left and attach it to the rail with a cable tie.
  • Page 31: Alarm Interface

    3. Insert the plug into the ALARM interface on the front panel of the BitStorm 2600. 4. If the BitStorm 2600 is in a rack, dress the cable to the left and secure it to the rail with a cable tie.
  • Page 32: Ground

    All manuals and user guides at all-guides.com 2. Cabling Ground Procedure To connect the unit to a ground: 1. Crimp a ring terminal onto the stripped end of 14 AWG or heavier copper ground wire. 2. Remove the screw marked by the ground symbol ( ) at the right side of the front panel.
  • Page 33: Connecting To Power

    1. Insert the supplied power cord into the power socket on the back of the unit. 02-17248 2. If the BitStorm 2600 is in a rack, dress the power cord to the left and fasten it to the rail with a cable tie.
  • Page 34 All manuals and user guides at all-guides.com 2. Cabling 2-12 January 2004 2600-A2-GN20-10...
  • Page 35: Leds

    All manuals and user guides at all-guides.com LEDs LED Locations The locations of the System and DSL Port LEDs on the front panel of the BitStorm 2600 are shown in Figure 3-1, Front Panel LEDs. Link LEDs Activity LEDS DSL Ports LEDs...
  • Page 36: Led Meanings

    All manuals and user guides at all-guides.com 3. LEDs LED Meanings When power is first applied to the unit, it performs a power-on self-test. When this test is successfully completed, the Status LED blinks. The meaning of all the LEDs is shown in Table 3-1, Front Panel LEDs.
  • Page 37: Configuration

    All manuals and user guides at all-guides.com Configuration Overview The BitStorm 2600 is designed to require minimal configuration before it can be accessed by a Network Operations Center (NOC). Initial configuration is performed using the Command Line Interface (CLI). The CLI is available from a terminal or PC connected to the CONSOLE port.
  • Page 38: Using The Cli

    All manuals and user guides at all-guides.com 4. Configuration Using the CLI A command line interface (CLI) can be used to configure and monitor the unit. The CLI is available from a PC or terminal connected to the Console port, or from a Telnet session with the device.
  • Page 39: Configure Management Inband Address

    All manuals and user guides at all-guides.com 4. Configuration Configure Management Inband Address The configure management inband address command specifies the IP address of the unit. configure management inband address {ip_address} { subnet_mask} Minimum Access Level: Administrator ip_address – Specifies the management IP address. Default is 0.0.0.0 (disabled). Do not configure inband and out-of-band management on the same subnet.
  • Page 40: Bitstorm 2600 Startup Procedure

    4. Configuration BitStorm 2600 Startup Procedure You can initialize your BitStorm 2600 via a PC or terminal connected to the unit’s CONSOLE port. Then, using a series of CLI commands, GrandVIEW EMS or another Element Management System, or the web interface, you can configure the unit according to your requirements.
  • Page 41: Startup Procedure For Inband Management

    All manuals and user guides at all-guides.com 4. Configuration Startup Procedure for Inband Management With inband management, the BitStorm 2600 is managed using the uplink port. Procedure To start up the BitStorm 2600 using inband management: 1. Specify the uplink port using the configure uplink command. It must be either eth2 (Port 2) or eth3 (Port 3).
  • Page 42: Using The Web Interface

    1. Open your web browser. (Internet Explorer Version 6 or above is recommended.) 2. Type http:// and the IP address of the BitStorm 2600 into the Address field of your browser window. For example: 3. A login window appears. Enter the default User ID (admin) and leave Password blank.
  • Page 43: System / Users

    All manuals and user guides at all-guides.com 4. Configuration System / Users For security reasons, it is a good idea to change the default password the first time you use the system. Procedure To change the default password for user admin: 1.
  • Page 44 All manuals and user guides at all-guides.com 4. Configuration management system addresses, and trap manager addresses can be set using the System/Management/SNMP screen. Procedure To set SNMP parameters: 1. Click on the Configuration menu tab, then click on SNMP. The System/Management/SNMP screen appears.
  • Page 45: Overview

    A-3 „ Port 3 GigE SFP Connector on page A-4 „ Console Port Connector on page A-5 „ ALARM Connector on page A-6 POTS 1-24 2600 DSL PORTS 1-24 03-17455 Figure A-1. BitStorm 2600 IP Front Panel 2600-A2-GN20-10 January 2004...
  • Page 46 All manuals and user guides at all-guides.com A. Connectors and Pin Assignments DSL Ports and POTS Splitter Connectors The 50-pin RJ21X Telco connector labeled DSL Ports 1–24 provides the 2-wire loop interface from each DSL port to the MDF for CO applications, or the in-building wiring for customer premises applications.
  • Page 47 All manuals and user guides at all-guides.com A. Connectors and Pin Assignments Port 1 and Port 2 10/100BaseT Connectors Port 1 and Port 2 are 8-pin unkeyed modular jacks for a 10/100Base interface. Table A-2. Port 1 and Port 2 Pinouts Signal Pin 8 Pin 1...
  • Page 48: Port 3 Gige Sfp Connector

    All manuals and user guides at all-guides.com A. Connectors and Pin Assignments Port 3 GigE SFP Connector Port 3’s GigE interface is a standard SFP socket. Table A-4. Port 3 GigE Connector Signal VeeT TXFault TXDisable MOD-DEF(2) – I2C_DATA MOD-DEF(1) – I2C_CLK MOD-DEF(0) –...
  • Page 49: Console Port Connector

    All manuals and user guides at all-guides.com A. Connectors and Pin Assignments Console Port Connector The CONSOLE port connector is a DB9 socket connector that supports an EIA-232-E circuit as shown in Table A-5. Table A-5. Console Port Connector RS-232 Signal Direction Pin Data Carrier Detect Receive Data...
  • Page 50: Alarm Connector

    All manuals and user guides at all-guides.com A. Connectors and Pin Assignments ALARM Connector The alarm relay reports major alarms through the ALARM connector. Table A-6. ALARM Connections Signal Direction Contact 5 4 3 2 1 Major Alarm Common Minor Alarm ALARM 03-17453 Alarm Sense +...
  • Page 51: B Equipment List

    All manuals and user guides at all-guides.com Equipment List Table B-1. BitStorm 2600 Equipment List (1 of 2) Description Model Number BitStorm 2600 and GranDSLAM 4200 IP Command Line Interface 2600-A2-GB21 Reference (paper copy) BitStorm 2600 and GranDSLAM 4200 IP SNMP Reference (paper...
  • Page 52 2621-A1-430 America power cord Includes BitStorm 2600, 19- and 23-inch mounting brackets and hardware, and Installation Guide. BitStorm 2600 ADSL with 600-Ohm POTS Splitter and UK power 2621-A1-434 cord Includes BitStorm 2600, 19- and 23-inch mounting brackets and hardware, and Installation Guide.
  • Page 53: C Technical Specifications

    30 VDC: 1.0 Amp Maximum Rated 60 VDC: 0.6 Amp Load 60 VAC: 0.6 Amp Cooling and Air Each BitStorm 2600 is independently cooled with integral fans and Handling does not rely on vertical air flow. Model 2611: Compatibility ReachDSL 2.2 Model 2621: G.dmt (G.992.1)
  • Page 54 All manuals and user guides at all-guides.com C. Technical Specifications Table C-1. BitStorm 2600 Technical Specifications (2 of 2) Specifications Criteria Operating Ambient Temperature: 0° to 50° C (32° to 122° F) Environment Relative Humidity: 5% to 95% noncondensing Storage Temperature: –40° to 85° C (–40° to 185° F)
  • Page 55: Index

    Port 3, A-4 audience for this document, iii autosensing, 2-4, 2-6 POTS splitter, A-2 CONSOLE port, 2-7 cabling and settings, 2-7 connecting modem, 2-8 BitStorm 2600 connector, A-3 description, 1-1 description, 1-3 features, 1-2 pin assignments, A-3 models, 1-2 pinouts, A-5...
  • Page 56 4-5 cabling, 2-1 initialization procedures, 4-4 configuration, 4-1 installation, 1-1 management modes, 4-4 options, 1-2 of BitStorm 2600, 1-1 installing of book, iii feet for shelf installation, 1-12 in rack, 1-8 mounting brackets for rack mount, 1-6 package contents, 1-4...
  • Page 57 All manuals and user guides at all-guides.com Index pin assignments, A-1 shelf installation, 1-12 Alarm, A-6 shipping carton, 1-4 CONSOLE port, A-3 site preparation, 1-2 Console port, A-5 site requirements, 1-2, C-2 Management port, A-3 SNMP, configuring parameters, 4-7 Port 3, A-3 specifications, related, iii Ports 1 and 2, A-3 stacking, 1-2...
  • Page 58 All manuals and user guides at all-guides.com Index IN-4 January 2004 2600-A2-GN20-10...