Paradyne IP Broadband Loop Carrier 12000E Installation Instructions Manual

Ip broadband loop carrier
Hide thumbs Also See for IP Broadband Loop Carrier 12000E:

Advertisement

Quick Links

12000E IP Broadband Loop Carrier
Installation Instructions
Document Number IPD1-A2-GZ40-10
July 2005
Contents

Software and Firmware License Agreement

The terms and conditions of this License Agreement (the "Agreement") will apply
to the software and/or firmware (individually or collectively the "Software")
incorporated into the Paradyne product (the "Product") purchased by you and any
derivatives obtained from the Software, including any copy of either. If you have
IPD1-A2-GZ40-10
........................................................................................................ 3
............................................................................................ 4
........................................................................................................ 19
..................................................................................................... 20
ONCE YOU HAVE READ THIS LICENSE AGREEMENT AND AGREE TO ITS
TERMS, YOU MAY USE THE SOFTWARE AND/OR FIRMWARE INCORPORATED
INTO THE PARADYNE PRODUCT. BY USING THE PARADYNE PRODUCT YOU
SHOW YOUR ACCEPTANCE OF THE TERMS OF THIS LICENSE AGREEMENT.
IN THE EVENT THAT YOU DO NOT AGREE WITH ANY OF THE TERMS OF THIS
LICENSE AGREEMENT, PROMPTLY RETURN THE UNUSED PRODUCT IN ITS
ORIGINAL PACKAGING AND YOUR SALES RECEIPT OR INVOICE TO THE
LOCATION WHERE YOU OBTAINED THE PARADYNE PRODUCT OR THE
LOCATION FROM WHICH IT WAS SHIPPED TO YOU, AS APPLICABLE, AND YOU
WILL RECEIVE A REFUND OR CREDIT FOR THE PARADYNE PRODUCT
PURCHASED BY YOU.
July 2005
...................................................... 1
......................................................... 3
.................................................................. 6
..................................................................... 9
............................................................... 14
..................................................................... 15
........................................................................ 18
.......................................................................... 18
............................................................................. 21
........................................... 23
1

Advertisement

Table of Contents
loading

Summary of Contents for Paradyne IP Broadband Loop Carrier 12000E

  • Page 1: Table Of Contents

    The terms and conditions of this License Agreement (the “Agreement”) will apply to the software and/or firmware (individually or collectively the “Software”) incorporated into the Paradyne product (the “Product”) purchased by you and any derivatives obtained from the Software, including any copy of either. If you have IPD1-A2-GZ40-10 ...
  • Page 2 Product purchased from Paradyne or its authorized distributor or reseller under the following terms and conditions: 1. Ownership: The Software is the sole property of Paradyne and/or its licensors. The Licensee acquires no title, right or interest in the Software other than the license granted under this Agreement.
  • Page 3: Introduction

    10. This Agreement shall be governed by the laws of the State of Florida, without regard to its provisions concerning conflicts of laws. Introduction Paradyne's 12000E IP Broadband Loop Carrier (BLC) provides a high capacity and native IP Ethernet foundation for a variety of feature-rich multi-service access multiplexer modules.
  • Page 4: Installation Options

    If there is visible damage, do not attempt to connect the device. Contact your sales representative. Installation Options The 12000E BLC is designed for installation in a Restricted Access area where admittance is limited to trained and authorized service personel. It may be installed on a tabletop or in a rack.
  • Page 5 Installing in a Rack Procedure 1. Using a Phillips screwdriver, attach the two provided rack mount brackets to the sides of the 12000E with eight of the ten provided bracket screws. There are seven position options for the rack brackets; position them as best suited to the space available for your chassis on the rack being utilized.
  • Page 6: Installing Your Management Module

    A management module provides the functional control for the 12000E BLC; the BLC cannot function without one. There are several different models available for purchase. Refer to www.paradyne.com for further information, or contact your sales representative. Installing a Management Module An uplink module provides the upstream network connection for the12000E BLC;...
  • Page 7 Procedure 1. Select a slot for installation. The 12000E is a fourteen slot chassis: slots 1–12 are reserved for interface modules and slots U1–U2 are reserved for management modules. Although the 12000E is shipped with Port U1 open, your management module can be installed in either Port U1 or Port U2. Only one management module is required for operational purposes.
  • Page 8 2. With the management module printed circuit board (PCB) facing right and the management module model name upright, align the upper and lower edges of the PCB with the slot module guides. 3. Slide the management module firmly into the chassis. Tighten the fastening screws on the management module faceplate.
  • Page 9: Installing Your Interface Module(S)

    12000E (slots 1–12). There are a variety of models available for purchase; contact your sales representative for further information or visit www.paradyne.com for a list of available products. Any combination of interface module models may be installed in an 12000E as long as they are supported by the model type and version number of your management module;...
  • Page 10 3. Slide the interface module firmly into the chassis. Tighten the fastening screws on the interface module faceplate. Fastening Screws July 2005 IPD1-A2-GZ40-10...
  • Page 11 Powering Up Your 12000E CAUTION: Turn your DC power source(s) OFF until you have completed connection of the 12000E as outlined in the following sections. Do not operate the 12000E without a ground connection. Procedure 1. Connect a ground wire to the 12000E: Line up the 2-hole terminal lug of your ground wire with the two holes on the small, unpainted section on the back of your chassis.
  • Page 12 3. Select a terminal block. Either terminal block on the back of the 12000E may be used to power the chassis; only one terminal block is required for operational purposes. The two terminal blocks on the 12000E are independent feeds. Chassis power is supplied by only one terminal block at a time; the second supply is a backup.
  • Page 13 4. Using a Phillips screwdriver, remove the left-hand screw from the chosen terminal block (labeled "+" on the chassis). Slide the ring terminal of your positive power lead around the shaft of the screw and insert the screw into the same "+"...
  • Page 14: Establishing Your Uplink Connections

    7. Verify the connection. Turn your power source(s) on. The PWR (power) LED on the interface module and management module faceplates will illuminate solid green to indicate the modules are receiving power. MANAGEMENT MODULE Establishing Your Uplink Connections No configuration is necessary for Uplink Interface Modules (UIMs) or Media Interface Modules (MIMs) installed on the management module(s) in your 12000E to operate at default settings.
  • Page 15: Connecting Your Subscriber Lines

    Connecting Your Subscriber Lines No configuration is necessary for the interface module(s) installed in your 12000E to operate at default settings. However, if you wish to run your subscriber connections at settings other than the defaults, configure the interface module(s) prior to connection.
  • Page 16 2. Detach the hook-and-loop fastener strap from the female RJ21 connector port: lift the hook-and-loop fastener tab on the left and pull the strap open towards the right, leaving it looped under the right side of the connector frame. FEMALE RJ21 CONNECTOR A FOR INTERFACE MODULE SLOT 3 3.
  • Page 17 5. Verify the connection(s). The LK (Link) LED for each port being connected with a remote modem will illuminate solid or flashing green (depending on the interface module model) to indicate a connection has been established. Link up time between interface modules and remote modems can vary from one to five minutes depending on the quality, gauge and distance of the copper cable pair(s) being used.
  • Page 18: Configuration And Management

    Guide Product Documentation Online Complete documentation for Paradyne products is available at www.paradyne.com. Select Support → Technical Manuals. To order a paper copy of a Paradyne document, or to speak with a sales representative, please call 1-727-530-2000. Contents module installation...
  • Page 19: Fan Module

    Fan Module The 12000E fan module is installed horizontally above the interface module slots. It comes pre-installed and should not be removed unless it is being replaced. Fan functionality is indicated by a FAN LED on the management module (all models): no illumination or solid green illumination indicates all fans are currently functioning, solid amber illumination indicates one or more of the four fans are no longer functioning.
  • Page 20: Specifications

    Specifications Table 1. Specifications Specification Environment Physical Power Regulatory Compliance Criteria Operating Temperature: –40° F to 149° F (–40° C to 65° C) Storage Temperature: –40° F to 158° F (–40° C to 70° C) Humidity: 5 % to 95 %, non-condensing Altitude: –200 ft to 16,500 ft (–60 m to 5,000 m) 15.75"...
  • Page 21: Important Safety Instructions

    Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. Do not attempt to service this product yourself, as opening or removing covers may expose you to dangerous high voltage points or other risks. Refer all servicing to qualified service personnel.
  • Page 22 The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Paradyne Corporation. July 2005 IPD1-A2-GZ40-10...
  • Page 23: Warranty, Sales, Service, And Training Information

    For additional information concerning warranty, sales, service, repair, installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one of the following methods: Internet: Visit the Paradyne World Wide Web site at www.paradyne.com. (Be sure to register your warranty at www.paradyne.com/warranty.) Telephone: Call our automated system to receive current information by fax or to speak with a company representative.
  • Page 24 *IPD1-A2-GZ40-10* *IPD1-A2-GZ40-10* July 2005 IPD1-A2-GZ40-10...

Table of Contents