Error code
Pict
E302
E305
E306
E307
E308
E431
E432
E433
E434
E437
Description of error
Confirmation of tilt of machine head
When tilt of machine head sensor is
OFF.
Thread trimmer knife position error
The thread trimmer knife is not in the
regular position.
Thread clamp position error
Thread clamp unit is not in the
regular position.
External input command time out error
Input is not performed for a fixed
period of time with the external input
command of vector data.
Time-out error of wait terminal
There is no input to wait terminal for
a certain period of time.
Outer presser is rising.
Proper operation has not been
performed.
Number of stitches has exceeded
the limit.
Hadware error has occurred.
Function cannot be selected.
message
– 194 –
How to recover Place of recovery
Possible to
Previous
re-start after
screen
reset.
Turn OFF
Data input
the power.
screen
Turn OFF
the power
Possible to
Data input
re-start after
screen
reset.
Turn OFF
the power
Possible to
Previous
re-start after
screen
reset.
Possible to
Previous
re-start after
screen
reset.
Possible to
Previous
re-start after
screen
reset.
Possible to
Previous
re-start after
screen
reset.
Possible to
Previous
re-start after
screen
reset.