7.0 Troubleshooting and correction

You have chosen the best quality and therefore deserve the best service. To avoid unnecessary disap-
pointments, you should check the following before contacting the nearest ALTO service organisation.
Fault
Motor refuses to start
Motor stops
Fuse blows
Pump pressure too high
Pump pressure fluctuating
Pressure too low but steady Nozzle worn
Motor starts but
no working pressure
*) Overcurrent release
activated
The machine can be restarted by turning the start button to position O. Wait until the motor has cooled.
Machines with automatic
start/stop:
The machine starts
irregularly by itself
Should other malfunctions occur than those mentioned above, please contact the nearest ALTO service
organisation.
Customer Services (only UK):
Cause
Plug not connected
Defective socket
Fuse blown
Extension cable defective
Overcurrent release activated
Fuse blown
Wrong mains voltage
Overcurrent release activated
Nozzle partly clogged up
High pressure hoses too long
Air in the water hose/pump
Inadequate water supply
Water filter clogged up
Hoses squeezed
High pressure hoses too long
Dirt in by-pass valve
Pump/hoses or accessories
frozen up
No water supply
Water fitler clogged up
Nozzle clogged up
Wrong mains voltage
Extension cable too long
Mains voltage fluctuating
Nozzle partly clogged up
Pump, high pressure hose, or
spray handle leaky
WAP/ALTO Cleaning Systems Ltd.
Gilwilly Industrial Estate
Penrith, Cumbria CA11 9BN
Correction
Connect plug.
Try another socket.
Change the fuse.
Try without extension cable.
Push the start button twice. *)
Change the fuse
Check that the mains voltage corresponds to
the specifications on the model tag.
Restart, turning the start button to position O. *)
Change to an installation higher than the am
pere consumption of the machine.
Clean the nozzle (see section 6.1)
(Check whether the water filter is missing).
Detach high pressure extension hoses and retry
(extension hoses max. 10 m).
Allow the cleaner to run with open spray handle
and the spray lance adjusted to low pressure
until the pressure is regular.
Check that the water supply corresponds to
specifications.
NB: Avoid long thin hoses (min. ½")
Clean the filter (see section 6.2).
Straighten out the hoses.
Detach high pressure extension hoses and retry
(extension hoses max. 10 m).
Change the nozzle
Activate and release the spray handle 5 times
in quick succession.
Let pump/hoses or accessories thaw out.
Connect the water supply.
Clean the filter (see section 6.2).
Clean the nozzle (see section 6.1).
See section 2.1.
See diagra, section 2.1.
Restart the machine.
Clean the nozzle (see section 6.1).
Contact your local ALTO service department.
Phone: 01 768 86 89 95