W TESTING
0 Turn on Gas and Water,
0 Test for water leaks and gas
escapes.
Use soapy water to check
for gas leaks.
0
Remove pressure
test point
screw, attach pressure
gauge to
test point.
0 Turn power on (Caution 230V
inside unit).
l Turn Infinity
16 on at Kitchen
Remote Control.
Set temp to 75%
(See page 7 and 8).
Open any hot water tap fully.
0
Check test point pressure.
Information
is provided
in a pouch,
rear of front panel.
l If the pressure
is low, there
could be various reasons
eg. warm
incoming
water, low,water
flow, gas
pipes too small.
Water flow will need to be at least 6
litres/min
if incoming
water temp. is
15oc.
0 If it is established
that the gas
pressure
needs adjusting,
follow the
instructions
EXACTLY
according
to the information
provided
in the
pouch, rear of front panel.
IF IN DOUBT, CONTACT
RINNAI.
0 Turn hot water off. Turn power
off. Remove pressure
gauge and
replace test point screw.
0
Replace front cover (4 stews).
0 Turn power on. Turn Infinity
16
ON at Remote Control.
0 Check operation
of appliance
by
ensuring
that the Remote Control(s)
are functioning
correctly.
0
Explain the operation
of the
Infinity
16 to the customer.
Make
sure the customer
understands
the
instructions,
in particular
the
instructions
for the Remote Control(s).
FAULT/FAILURE PROCEDURE
If you are unable to get the Infinity
16 to operate correctly,
contact
Rinnai, or your local agent.
Test
point
Screw
and washer
SET CONTROL
HOT WATER TAP OPEN
NOTE: The regulator is factory pre-set, it
should not need adjusting. Check incoming
pressure before attempting to make any
change to the appliance regulator.