Figure 17 Connecting the grounding cable to the chassis
(1) Grounding screw
(3) Grounding sign
(5) Grounding cable
Connecting the grounding cable to a grounding strip (for the HPE 5510 24G PoE+ 4SFP+ HI
and HPE 5510 48G PoE+ 4SFP+ HI switches)
Remove the hex nut of a grounding post on the grounding strip.
1.
Cut the grounding cable to a length required for connecting to the grounding strip.
2.
Attach a ring terminal to the grounding cable:
3.
a. Use a wire stripper to strip 5 mm (0.20 in) of insulation off the end of the grounding cable.
b. Slide the heat-shrink tubing onto the cable and insert the bare metal part into the end of the
ring terminal.
c. Use a crimper to secure the metal part of the cable to the ring terminal.
d. Slide the heat-shrink tubing down the cable until the tube covers the joint.
e. Use a heat gun to shrink the tubing around the cable.
Figure 18 Attaching a ring terminal to the grounding cable
Connect the ring terminal to the grounding post of the grounding strip, and fasten it with the
4.
removed hex nut.
(2) Ring terminal
(4) Grounding hole