Denon S-301 Service Manual page 68

Hide thumbs Also See for S-301:
Table of Contents

Advertisement

TAS5121 (IC101, 201, 301, 401: 1U-3683)
TERMINAL
FUNCTION (1)
FUNCTION (1)
NAME
DKD
BST_A
22
BST_B
33
DGND
9, 14
DREG
8
DREG_RTN
5
DVDD
12
GND
1, 3, 16,
18, 21,
27, 28,
34
GVDD
6
GVDD_A
19, 20
GVDD_B
35, 36
M1
10
M2
11
M3
7
OTW
15
OUT_A
25, 26
OUT_B
29, 30
PVDD_A
23, 24
PVDD_B
31, 32
PWM_AP
17
PWM_BP
2
RESET
4
SD
13
(1) I = input, O = Output, P = Power
GND
1
PWM_BP
2
GND
3
RESET
4
DREG_RTN
5
GVDD
6
M3
7
DREG
8
DGND
9
M1
10
M2
11
DVDD
12
SD
13
DGND
14
OTW
15
GND
16
PWM_AP
17
18
GND
Terminal Functions
P
High-side bootstrap supply (BST), external resistor and capacitor to OUT_A required
P
High-side bootstrap supply (BST), external resistor and capacitor to OUT_B required
P
I/O reference ground
P
Digital supply voltage regulator decoupling pin, 1-µF capacitor connected to DREG_RTN
P
Decoupling return pin
P
I/O reference supply input: 100 Ω to DREG, decoupled to GND, 0.1-µF capacitor connected to
GND
P
Power ground, connected to system GND
P
Local GVDD decoupling \pin
P
Gate drive input voltage
P
Gate drive input voltage
I
Protection mode selection pin, connect to GND
I
Protection mode selection pin, connect to DREG
I
Output mode selection pin; connect to GND
O
Overtemperature warning output, open drain with internal pullup resistor, active-low when temper-
ature exceeds 115°C
O
Output, half-bridge A
O
Output, half-bridge B
P
Power supply input for half-bridge A
P
Power supply input for half-bridge B
I
PWM input signal, half-bridge A
I
PWM input signal, half-bridge B
I
Reset signal, active-low
O
Shutdown signal for half-bridges A and B (open drain with internal pullup resistor), active-low
GVDD_B
36
GVDD_B
35
GND
34
BST_B
33
PVDD_B
32
PVDD_B
31
OUT_B
30
OUT_B
29
GND
28
GND
27
OUT_A
26
OUT_A
25
24
PVDD_A
23
PVDD_A
22
BST_A
21
GND
20
GVDD_A
19
GVDD_A
DESCRIPTION
DESCRIPTION
68
S-301

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents