Taking Care Of The Guide Bar; Cleaning The Air Filter - Stihl MS 200 Instruction Manual

Hide thumbs Also See for MS 200:
Table of Contents

Advertisement

Available languages

Available languages

English
Taking Care of the Guide
Bar
2
1
N
Turn the bar over – every time you
sharpen the chain and every time
you replace the chain – this helps
avoid one-sided wear, especially at
the nose and underside of the bar.
N
Regularly clean the oil inlet hole (1),
the oilway (2) and the bar
groove (3).
N
Measure the groove depth – with
the scale on the filing gauge (special
accessory) – in the area used most
for cutting.
Chain type Pitch
Minimum
groove depth
Picco
3/8" P
5.0 mm
Rapid
1/4"
4.0 mm
Rapid
3/8"; 0.325" 6.0 mm
Rapid
0.404"
7.0 mm
26
If groove depth is less than specified:
N
Replace the guide bar.
The drive link tangs will otherwise
scrape along the bottom of the groove –
the cutters and tie straps will not ride on