6. ALARMS
Message and meanings
Message
XTE ALARM!
TIME ALARM!
SPEED ALARM!
ARRIVAL ALARM!
TRIP ALARM!
ODOMETER ALARM!
ANCHOR WATCH!
NO WAAS SIGNAL!
Note: The message screen also shows equipment trouble. See section 8.3.
6.2

Buzzer Type Selection

The buzzer sounds whenever an alarm setting is violated. You can select the type of
buzzer as follows:
1. Press the MENU key twice to show the main menu.
2. Select [Alarms], and press the ENT/CNTR key.
3. Select [Buzzer], and press the ENT/CNTR key.
4. Select buzzer type, and press the ENT/CNTR key.
Short: Unit emits a short beep sound for 1 second and off for 1 second.
Long: Unit emits a long beep sound for approximately 3 seconds for three times.
Continuous: Unit continuously emits long beep sounds until a key is pressed.
5. Press the MENU key twice to close the menu.
6-2
The boat is off its intended course by the range set.
The time set has come.
The boat's speed is higher than the range set.
The boat is approaching the arrival area.
The boat has traveled further than the preset trip distance.
The boat has traveled the total distance set.
The boat has moved a certain distance (when it should be at
rest).
WAAS signal cannot be found.
Meaning