No.
Adjustment Item
69
Auto Watt Max Fan1 Min
1560/1545/1680/2580
70
Auto Watt Max Fan2 Min
3240/3285/3450/4620
71
Auto Watt Max Fan3 Min
2235/2235/2415/3300
72
Auto Watt Max Fan4 Min
2580/2580/2820/4335
73
Auto Watt Max Fan1 Max
2490/2490/2490/2760
74
Auto Watt Max Fan2 Max
3375/3465/3375/4530
75
Auto Watt Max Fan3 Max
3045/3045/3045/3675
76
Auto Watt Max Fan4 Max
5055/5055/5340/4965
77
Auto Watt Min Fan1 Min
1245/1680/1860/2085
78
Auto Watt Min Fan2 Min
2235/2265/2220/3405
79
Auto Watt Min Fan3 Min
1605/2340/2520/3045
80
Auto Watt Min Fan4 Min
1815/1815/1815/3900
81
Auto Watt Min Fan1 Max
2325/2325/2310/2715
82
Auto Watt Min Fan2 Max
2670/2655/2550/3600
83
Auto Watt Min Fan3 Max
1935/2640/2835/3360
84
Auto Watt Min Fan4 Max
4125/4905/5025/4740
85
Auto TempA Low
86
Auto TempA High
87
Auto TempB Low
88
Auto TempB High
89
Auto TempC Low
90
Auto TempC High
91
Auto TempA Error
92
Auto TempB Error
93
Auto TempC Error
94
Auto TempB-A Error
95
Auto TempC-A Error
96
Cooling Time
97
Temp Error Cooling Time
98
Average Time
99
Change Normal
101
Dac Change Speed
102
Fan1 Initial Vol
103
Fan2 Initial Vol
104
Fan3 Initial Vol
105
Fan4 Initial Vol
106
Fan Keep Time
107
Fan Min Keep Time
108
Shutdown Temp A
109
Shutdown Temp B
110
Shutdown Temp C
111
Shutdown Temp B-A
112
Shutdown Temp C-A
113
Shutdown Time A
114
Shutdown Time B
115
Shutdown Time C
116
Shutdown Time B-A
117
Shutdown Time C-A
122
Fan Min Interlock
125
Lamp Monitor SW
126
Lamp Voltage
127
Lamp Vol Threshold
128
Fan Speed Gain
129
Lamp Keep Time
Group: 103 Lens IRIS
0
Iris Descriptor Min
1
Iris Descriptor Max
2
Iris Valid
3
Iris ADC Value
Group: 104 Door Control
0
Door Control Brake
1
Door Control First
2
Door Control Open
3
Door Control Close
4
Door Control Extra
5
Door Control Limit
6
Door Control Initialize
7
Door Control Count OPEN
8
Door Control Count CLOSE
9
Door Control Reset OPEN
10
Door Control Reset CLOSE
11
Door Control Exhibition
12
Door Control Blink Time
Group: 105 Lamp IRIS
0
Lamp IRIS Mecha A
1
Lamp IRIS Mecha B
2
Lamp IRIS PWM Time
3
Lamp IRIS Margin
4
Lamp IRIS Point C
5
Lamp IRIS Point O
6
Lamp IRIS Min X
Initial Value
Range
Input source / Description
510 - 4500
510 - 6510
510 - 4500
510 - 6510
510 - 4500
510 - 6510
510 - 4500
510 - 6510
510 - 4500
510 - 6510
510 - 4500
510 - 6510
510 - 4500
510 - 6510
510 - 4500
510 - 6510
27/27/27/25
-5 - 100
35/35/35/30
-5 - 100
53/52/51/52
-5 - 100
58/57/56/55
-5 - 100
46/46/46/42
-5 - 100
51/51/51/47
-5 - 100
41/41/41/31
-5 - 100
59/59/57/56
-5 - 100
52/52/52/48
-5 - 100
38/38/38/30
0 - 100
26/28/26/28
0 - 100
2
0 - 15
3
1 - 15
1
0 - 10
0
0 - 1
2
1 - 10
50
0 - 255
40
0 - 255
50
0 - 255
40
0 - 255
15
0 - 180
60
0 - 180
5
0 - 100
20
0 - 100
5
0 - 100
20
0 - 100
20
0 - 100
240
0 - 255
240
0 - 255
240
0 - 255
240
0 - 255
240
0 - 255
0
0 - 1
1
0 - 1
---
30 - 90
60
50 - 90
300
0 - 1500
90
0 - 255
120
0 - 255
230
0 - 255
1
0 - 1
---
0 - 255
16
1 - 16
0
0 - 2000
900
0 - 2000
900
0 - 2000
300
0 - 2000
5000
0 - 20000
400
0 - 2000
---
0 - 30000
---
0 - 30000
1
0 - 1
1
0 - 1
0
0 - 1
2
0 - 10
50
1 - 254
200
1 - 254
200
100 - 1000
5
0 - 63
4/4
0 - 255
64/64
0 - 255
0/22
0 - 63
0: Always ON, 1: 30sec, 2:60sec, 3: 90sec, ... 15: 450sec.
1: 30sec, 2: 60sec, 3: 90sec, ... 15: 450sec.
0:10sec, 1: 30sec, 2: 60sec, 3: 90sec ... 10: 300sec
0: Normal, 1: Forced lamp MAX
FAN MIN Interlock On/Off (0: Individual, 1: Link)
0: Off, 1: On
Read only
0: Disable, 1: Enable
Read only
Read only
Read only
Shutter demonstration(0: Normal demo, 1: Exhibition demo)
0: Always, 1: 30sec, 2: 60sec ... n: 30n sec.
(AUTO1/AUTO2)
(AUTO1/AUTO2)
(AUTO1/AUTO2)