Optical adjustment
3.
Integrator lens adjustment-2
1. Adjust the 2 slots F to make color uniformity in white by using a slot screwdriver.
(Top and bottom shading are erased.)
Note;
Slot F is moved in parallel by operating the right and left simultaneously. Otherwise, the integra-
tor lens rotates. Refer to "1 Integrator lens adjustment-1".
2. Adjust the slots E to make color uniformity in white by using a slot screwdriver.
(Right and left shading are erased.)
3. Tighten 2 screws A and screw B to fix the integrator lens unit.
Slot-F
Slot-F
SCREW-C
Screw-B
Screws-A
CYAN
CYAN
SLOT-D
Slot-E
- 50 -
CYAN
White
White
MAGENTA
MAGENTA
White
White
MAGENTA