Sanyo PLV-Z4 Service Manual page 56

Hide thumbs Also See for PLV-Z4:
Table of Contents

Advertisement

Electrical Adjustments
c
Video signal center adjustment
Equipment
Digital voltmeter
Input mode
Computer [RGB(Analog)]
Image mode
Powerful
Input signal
16-step gray scale computer signal
(720p format)
1. Enter the service mode.
2. Change data values for each test points to adjust the
video signal center voltage (VMID).
Item no.
Test Point
2 - 0
TPVG
2 - 1
TPVB
2 - 2
TPVR
v
Reference adjustment
Equipment
Digital voltmeter
Input mode
Computer [RGB(Analog)]
Image mode
Powerful
Input signal
16-step gray scale computer signal
(720p format)
1. Enter the service mode.
2. Change data value for each test points to adjust the
video signal reference voltage (VREF).
Item no.
Test Point
2 - 3
TPREFG
2 - 4
TPREFB
2 - 5
TPREFR
Adjustment value
7.0
±0.05Vdc
7.0
±0.05Vdc
7.0
±0.05Vdc
Adjustment value
9.5
±0.05Vdc
9.5
±0.05Vdc
9.5
±0.05Vdc
b
Sub gain adjustment
Equipment
Oscilloscope
Input signal
16-step gray scale signal
5-a Input mode
Computer [RGB(Analog)]
Image mode Powerful
Input format
720p computer signal
5-b Input mode
Video
Image mode Powerful
Input format
NTSC composite video signal
5-c Input mode
Component_1
Image mode Powerful
Input format
480i component signal
5-d Input mode
Component_1
Image mode Powerful
Input format
480p component signal
5-e Input mode
Component_1
Image mode Powerful
Input format
720p component signal
5-f Input mode
Component_1
Image mode Powerful
Input format
1080i component signal
1. Enter the service mode.
2. Change data values for each test points to adjust the
waveform "a" to be minimum amplitude in each
mode.
Item no.
Test Point
106 - 0
TP35G
106 - 1
TP35B
106 - 2
TP35R
(a)
-56-