Optical disassemblies
26
Optical base top removal.
1.Remove the 7 screws-A(T3x10) and remove the Optical base top.
27
-1
Lamp iris unit and Relay lens ass'y removal.
1.Remove the 2 screws-A(M2x2), remove the Shield plate
and remove the Lamp iris unit.
2.Remove the screw-A(M2.5x5) and remove the Relay lens
(OUT) ass'y.
A
A
A
Shield plate
Lamp iris unit
Fig. 27-1
- 38 -
A
A
A
A
Optical base top
Fig. 26
A
A
Relay lens(OUT) ass'y
B