General Instructions; Scope Of Delivery - Spartherm NOVA E H2O Installation And Operating Manual

Table of Contents

Advertisement

1. GENERAL INSTRUCTIONS

Prior to setup and installation of the tiled stove system, Nova E H
discussion must be conducted with your responsible district master chimney
sweep. He will advise you of building law regulations, the suitability of your
chimney, and will execute the acceptance procedure of your tiled stove. The
chimney calculation is executed in accordance with DIN EN 13384 with the
value triplet specified in this manual (see technical data).
OUR HEATING INSERT HAS BEEN TESTED IN ACCORDANCE WITH
DIN EN 13229 AND SATISFIES THE REQUIREMENTS STIPULATED
IN THE CONSTRUCTION PRODUCTS DIRECTIVE. (DECLARATION
OF PERFORMANCE IS AVAILABLE AND CAN BE VIEWED AT WWW.
SPARTHERM.COM)
Small children, elderly or infirm persons: As is the case with all heating
devices, it is expedient that you attach a protective fixture for these groups
of persons, as the view pane and also the cladding parts can become
extremely hot! Danger of burn injuries! Never leave these groups of persons
unattended near the fireplace when a fire is burning or has just been
extinguished!
National and European standards, the respective state-specific and local
directives and regulations, in particular the respective firing installation
ordinance of the German Federal State, must be complied with for the setup
and operation of your insert and for the connection to the chimney. For
improved capacity utilisation of the high flue gas temperatures a water heat
exchanger is integrated on the walls and in the flue gas collector. A service
water storage tank, buffer tank, etc. can be heated with the generated hot
water. If these or similar system components are not available, then through
other structural measures, safe and continuous heat dissipation must be
ensured.
The fireplace must always be operated with a self-closing door. Modification
of the closing device is prohibited! Coasting temperature surfaces can/must
be integrated in the connecting line to the chimney. These downstream
O, a
heating surfaces must only reduce the flue gas temperature to the extent
2
possible for safe and suitable operation of the flue gas system! The Nova E
H
O insert serves as a supplemental heat generator for
2
water heating systems in accordance with DIN EN 12828, as the specified
nominal heat output only occurs as long as the insert is fired with nomi-
nal heat output. The fireplace can be operated manually or with suitable
combustion controllers and appropriate settings. If necessary, consult with
Spartherm Feuerungstechnik GmbH in this regard.

1.1 SCOPE OF DELIVERY

Nova E H
O with the following features:
2
• Insert with integrated water heat exchanger and hinged door.
• Safety heat exchanger and vent plug.
• Thermal discharge safety device (TAS) ¾" with immersion sleeve ½" and
capillary tube length of 4.0 m, e.g. from the company Watts, STS 20/400
• Immersion sleeve for the thermostat switch for circulation pump
• Thermostat switch for circulation pump with capillary tube (length = 2.0
m), Afriso GTK 7/HD
• Cleaning brush
• Flue gas outlet
The following components are available as options:
• Return flow boost (ESBE; type: LTC 141)
• ZAccessories for the heater installation, e.g. safety valve, membrane
expansion vessel, etc.
• S-Thermatik, combustion controller with temperature display for buffer
tank temperature
GB 4