Advertisement

Quick Links

Installation and Operating Manual
ebios fire - Tower
GB 1
GB 1
GB
GB

Advertisement

Table of Contents
loading

Summary of Contents for Spartherm ebios fire Tower

  • Page 1 Installation and Operating Manual ebios fire - Tower GB 1 GB 1...
  • Page 2 FOREWORD / QUALITY PHILOSOPHY You have chosen a SPARTHERM ebios-fire. Thank you for your confidence in our technology. In a world characterised by excess and mass production, the good name of our firm is inextricably linked to the credo of our owner, Gerhard Manfred Rokossa: “High technical quality combined with modern design and on-site customer...
  • Page 3: Table Of Contents

    CONTENTS 1. General Information 5. Troubleshooting and audible signals 1.1 Scope of Supply 5.1 Operating signals and fault signals (audible signals) 5.2 Unit and glass soot up heavily, quickly and unevenly 2. Installation Instructions 5.3 Unpleasant smell 2.1 Functional description 5.4 Flame pattern changes 2.2 Technical data 5.5 Burner fails to light...
  • Page 4: General Information

    1. GENERAL INFORMATION IMPORTANT INFORMATION Young children, the elderly and the frail: As with all naked flames, a guard As per the German Equipment and Product Safety Act (GPSG) and our should be used to protect the above. Risk of burns! Never leave such statutory duty to notify, we would like to inform you about heating with this individuals unsupervised near an ebios-fire when it is lit or when the fire product.
  • Page 5: Scope Of Supply

    2.1 FUNCTIONAL DESCRIPTION For homes in Germany the general rule is: Storage in the basement: not more than 20 litres Storage in the living-room: not more than 5 litres Once the operating voltage is applied to the burner (via battery or charger), pressing the switch behind the flap door in the base will switch it to opera- (Source: Hazardous Substances Information Data Sheet published by the Association of the Raw Materials tional mode.
  • Page 6: Technical Data

    If the canister(s) is/are empty, the flame will go out and the burner will ** The following air change values are quoted as a rough guide switch off. Additional an audible fault signal will be heard. Air change (l/h) Note The pumps stop when the burner switches off.
  • Page 7: Installation Location

    There must be no fuel in the fire tray during transport. When setting up the ethanol canisters (not in the Tower) it is important to ensure that they cannot tip over. In addition, the design of the location must DAMAGE IN TRANSIT Please contact your supplier without delay. Protect the ensure that it does not allow flammable gases to build up, it will contain any cover and visible parts of your fire from dirt and damage during installation escaping ethanol and it will prevent fire from spreading.
  • Page 8: Combustion Air Supply

    doors are sealed (for example, for energy-saving reasons) it may be the case that an adequate fresh air supply cannot be guaranteed. That is why it is essential that you note the required air change rate and comply with the room sizes indicated.
  • Page 9: Fuel

    • The burning process releases thermal energy which heats up the • Handling fuel near the unit when lit or while still hot is dangerous and burner, the housing surfaces and the glass windows. Do not touch! must be avoided. Please remember that a static charge is enough to Risk of burns create a spark which can ignite the fuel.
  • Page 10: Using The Unit For The First Time

    3.3.1 ASSEMBLY AND INSTALLATION Ethanol is a highly flammable fluid which must be stored in a tightly closed container in a cool place, protected from light and kept away from sources of ignition. Please remember that a static charge can create a spark. It is 1.
  • Page 11: Starting The Ebios-Fire

    5. Place the canisters at the On / Off button On / Off button requisite locations on the pillar base. Connect the suction hoses to the filler adapters using quick- release couplings. (Fig. 4) Fig. 4 Fig. 6 Fig. 6a If you only wish to use one container, Please note: if you switch off the appliance while it is still warm, you pull the quick-release coupling off the unused filler adapter, or attach the...
  • Page 12: Checks When Using The Fire For The First Time

    3.3.3 CHECKS WHEN USING THE FIRE FOR THE FIRST or if the fuel does not ignite, switch the unit off. Unplug the wall power TIME supply from the socket and contact Customer Service. 5. Flame height adjustment If you do not have a checklist for this, please answer the following questions: 2nd flame stage 2nd flame stage •...
  • Page 13: Shutting Down The Unit

    3.5 SHUTTING DOWN THE UNIT If the unit is not going to be used for some time, remove the fuel lines from the canisters before switching off, and then wait for the signal that both canisters are empty. That ensures that the fuel lines have been drained as much as possible.
  • Page 14: Troubleshooting And Audible Signals

    5. TROUBLESHOOTING AND AUDIBLE SIGNALS 5.1 OPERATING SIGNALS AND FAULT SIGNALS (AUDIBLE SIGNALS) Bild 13 Operating signals: • Carefully lift off the grate containing the granules from the fire tray. • 2 x short beeps when switching on = signal that the burner is starting •...
  • Page 15: Unit And Glass Soot Up Heavily, Quickly And Unevenly

    5.2 UNIT AND GLASS SOOT UP HEAVILY, QUICKLY 5.5 BURNER FAILS TO LIGHT AND UNEVENLY • Is the ring on the switch showing red? If this has not always been the case, please check the following: • Is there ethanol in the canisters? •...
  • Page 16: General Warranty Terms And Conditions

    They are not the same as the contract and warranty claim. If such proof is not produced Spartherm Feuerungstechnik GmbH terms and conditions which the dealer/intermediary passes on or may pass shall not be obliged to honour the warranty.
  • Page 17: Defect Remediation / Repairs

    6.9 LIABILIT Y Damage and compensation claims not based on a defective unit supplied by Spartherm Feuerungstechnik GmbH are excluded and are not covered by the warranty undertaking. This does not apply to statutory warranty claims arising in a particular case.
  • Page 18: Dimensioned Drawings

    7. DIMENSIONED DRAWINGS Proprietorship of the manufacture and design is expressly reserved and full legal protection is claimed in accordance with Sections 823, 826 and 1004 of the German Civil Code. Unauthorized copying, distribution and reproduction, in full or in part, will be subject to civil and criminal prosecution under Sections 2 (7), 96 ff and 106 ff of the German Copyright Act and Sections 1, 3, 4, 18 and 19 of the Unfair Competition Act.
  • Page 19 NOTES GB 19...
  • Page 20 IT Il vostro rivenditore specializzato | E Sus comercios especializados NL Uw vakhandelaar | PL Państwa sprzedawca | РУС Ваш дилер SPARTHERM Feuerungstechnik GmbH · Maschweg 38 · D-49324 Melle Phone +49 (0) 5422 94 41-0 · Fax +49 (0) 5422 9441-14 · www.spartherm.com GB 20...

Table of Contents