INSTALLATION
21) Stick the conversion label "This unit has
been converted to LPG" on the control box
cover.
22) Reverse steps 19 and 18.
23) Turn on gas supply and plug in power
cord.
24)
Adjusting the Outlet Pressure
All the adjustments must be carried out
in the following order:
Remove the modulator plastic cap (A) using
needle nose pliers.
Maximum pressure: Turn the unit ON to
its highest input rating. Screw in the nut (B)
to increase the outlet pressure and screw it
out to decrease it. Use a 10 mm wrench.
NOTE: The outlet pressure must be set to
maximum 2.75 kPa.
Minimum pressure: Remove one of the
cables connected to the electric modulator.
Keeping the nut (B) blocked, screw in the
screw (C) to increase the pressure and
screw it out to decrease it. Use a screwdriver
6 x 1 blade.
NOTE: The outlet pressure must be set to
minimum 0.72 kPa.
After carrying out all adjustments, block
the setting screws with paint, taking care
not to obstruct the breather orifi ce of the
pressure.
Put back the modulator plastic cap.
WARNING: To ensure the correct operation
of the modulator it is necessary that the
plastic cap (A) is returned to its original
location.
20
B
25) At the end of all setting and adjustment
operations, check electrical insulation and
gas leaks.
26) Check operation of fl ame control.
27) Check for proper fl ame appearance and glow
on logs.
Installer Notice:
These instructions must be left
with the appliance.
Cable
Electric
Modulator
A
C