Siemens OP5 Equipment Manual page 130

Operator panel
Table of Contents

Advertisement

Maintenance
Warning
!
Replacing battery
Before you replace a battery, take note of the following:
Caution
!
Note
Make sure the voltage supply is switched on when you replace a battery to
prevent a loss of data.
To replace a battery, proceed as follows:
1. Remove the battery cover and take the battery from its holding device.
2. Pull off the connector on the battery lead.
3. Insert the new battery in reverse order.
Caution
!
Spent lithium batteries should be treated as special waste. Pack them sepa-
rately in leakproof plastic bags for disposal.
20-2
With improper handling, there is a risk of lithium batteries exploding.
Batteries
– must never be charged,
– must not be opened,
– must not be short-circuited,
– must be protected against polarity reversal,
– must not heat to more than 100 C,
– must be protected from direct sunshine.
Humidity should not be allowed to condense on batteries.
Should transportation become necessary, the forwarding agent concerned
must comply with the Dangerous Chemicals Ordinance (obligatory labe-
ling).
Battery replacement may be performed only by qualified persons.
Before replacing a battery, study the ESD guidelines in the appendices to
this manual.
Manual OP5, OP15
( ) J31069-D0840-U001-A2-7618

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Op15