MAINTENANCE GUIDE: GENUS HE SYSTEM
4.4
FAN
Tools
1
Remove the combustion
assembly (see 4.3)
1. Venturi
2. Gasket
3. Fan
Page. 18 of 20
Supplied By www.heating spares.co Tel. 0161 620 6677
FAN
Remove the three screws to free the
fan.
Twist the gas valve anti-clockwise to
disengage it from the fan
Fan & mixer venturi according to the model
Power
Fan
25 KW
EBM RG 128 45 W
30 KW
EBM RG 128 45 W
38 KW
EBM RG 128 45 W
MAINTENANCE GUIDE
Time
15 min
Venturi diameter
Ø 17 mm
Ø 21 mm
Ø 25 mm