description
2 4 BOILER PARAMETER - PART 2
2 4 0
NOT PRESENT
2 4 1
NOT PRESENT
2 4 2
NOT PRESENT
2 4 3 Post-ventilation after heating request
2 4 4 Time delay after heating temperature increase
This parameter allows the time delay to be set before automatic increase of the flow temperature calculated in increments of 4°C (max 1°C). If this
parameter retains the value 00, this function is not active.
2 4 5
NOT PRESENT
2 4 6
NOT PRESENT
2 4 7 Device indicator for heating circuit pressure
2 4 8 NOT PRESENT
2 5 DOMESTIC HOT WATER PARAMETER (COMBI BOILERS ONLY)
2 5 0 COMFORT function - NOT ACTIVATED
2 5 1 Comfort Anti-cycling Time - NOT ACTIVATED
2 5 2 Hot water flow delay - NOT ACTIVATED
2 5 3 Extinction of the burner in domestic hot water - NOT ACTIVATED
2 5 4 Post-circulation and post-ventilation after a
domestic hot water draw-off
2 5 5 Domestic hot water timer
2 9 RESET MENU 2
2 9 0 Automatically resetting to the default setting in
menu 
Supplied By www.heating spares.co Tel. 0161 620 6677
settings - adjustment - problem identification menus
value
0 = OFF
1 = ON
from 0 to 60 minutes
0 =
temperature sensor only
1 = pressure switch at mini-
mum
 = pressure sensor
0 = OFF
1 = ON
OFF = 3 minutes post-circulation and post-ventilation after domestic hot water
draw-off if the boiler temperature measured requires it.
ON = always on for 3 minutes post-circulation and post-ventilation after domestic
hot water draw-off.
from 0 to 60 minutes
Reset
OK = yes
ESC = no
0
16
activated only with thermostat On/Off and
heating control activated (parameter 41 or 51
= 01
1
RESERVED FOR TECHNICAL ASSISTANCE Only if the
PCB is changed
0
0
To reset all default parameter settings, press the
MENU button
39