settings - adjustment - problem identification menus
description
5 ZONE 2 PARAMETER
5 0
ZONE 2 TEMPERATURE SETTING
5 0 0 Zone  comfort temperature setting
"Comfort ambience T"
5 0 1 Zone  reduced temperature setting
"Reduced ambience T"
5 0 2 Heating fixed temperature setting
"Heating fixed temp"
5 1 Entering access code
5 2 ZONE 2 SETTING
5 2 0 Heating appliance temperature value
setting
5 2 1 Basic heating control type selection type
depending on the peripheral devices
connected
5 2 2 Slope
If the external sensor is used, the boiler calculates the most suitable heating flow
temperature taking the external temperature and the type of appliance into
account.
The type of curve must be chosen according to the type of appliance radiator and the
heat losses present in the building.
5 2 3 Parallel shift
To adapt the thermal curve to the appliance requirements, it is possible to perform a parallel shift of the curve in order to alter the calculated
flow temperature and therefore the ambient temperature.
The shift value between - 0 and + 0 is shown on the display. Each level corresponds to a 1°C increase in the flow temperature in relation to
the initial setting.
5 2 4 Compensation
5 2 5 Zone  heating maximum temperature
setting
5 2 6 Zone  heating minimum temperature
setting
5 3 DIAGNOSTICS
5 3 0
Zone  room temperature
5 3 1
Heating flow outlet temperature
5 3 2
Heating return temperature
5 3 3
Zone  set temperature
5 3 4
Zone  heat request
5 3 5
Zone  Pump status
5 4 ZONE DEVICE MANAGEMENT
5 4 0
Operation mode test
5 4 1
Valve control
5 4 2
Pump control
5 5 MULTIZONE
5 5 0
Heating collector temperature
5 5 1
Heating collector flow outlet
temperature offset
4
Supplied By www.heating spares.co Tel. 0161 620 6677
value
from 10 to 30 °C
from 10 to 30 °C
from 0 to 8 °C
0 = from 0 to 45°C (low
temperature)
1 = from 35 to 85°C (high
temperature)
0 = fixed flow temperature
1 = device On/Off
 = ambient sensor only
3 = external sensor only
4 = ambient sensor + external
sensor
0_ to 3_5
- 0 to + 0
0 to + 0
if setting = 0, the temperature taken from the ambient sensor does not affect the calculation of the
setting. If setting = 0, the temperature taken has maximum influence on the setting.
35 to + 8°C
0 to + 45°C
35 to + 8°C
0 to + 45°C
0=OFF
1=ON
0=OFF
1=ON
0=OFF
1=ON
=manual
0=OFF
1=Open
=Close
0=OFF
1=ON
0 to 10°C
0 to + 40°C
19 Activated only with the modulating device connected
(option)
16
70 Activated only with temperature control and fixed
temperature
 turn the encoder clockwise to select 34 and press
the M
/o
button
enu
k
1
select in the appliance type base
0
To activate heating control, press the AUTO button.
The display lights up the AUTO symbol, indicating the
peripheral device connected (if present)
1_5
see graph on the previous page
0
0
8 if parameter 50 = 1
45 if parameter 50 = 0
35 if parameter 50 = 1
0 if parameter 50 = 0
Activated only with the modulating device connected
(option)
Active only with MGZ/MCM kit
Activated only with the modulating device connected
(option)
Active only with MGZ/MCM kit
Active only with MGZ/MCM kit
0
Active only with MGZ/MCM kit
5