Fan Unit - Ariston Genius he 24 Installation And Servicing Instrucnions

Gas fires condensing wall hung combination boilers
Table of Contents

Advertisement

MAINTENANCE GUIDE
MAINTENANCE GUIDE: GENUS HE
4.4
FAN
Tools
1
Remove the combustion
assembly (see 4.3)
1. Venturi
2. Gasket
3. Fan
60
Supplied By www.heating spares.co Tel. 0161 620 6677
FAN
Remove the three screws to free the
fan.
Twist the gas valve anti-clockwise to
disengage it from the fan
Fan & mixer venturi according to the model
Power
Fan
24 KW
EBM RG 128 45 W
30 KW
EBM RG 128 45 W
38 KW
EBM RG 128 45 W
Time
15 min
Venturi diameter
Ø 17 mm
Ø 21 mm
Ø 25 mm
Page. 21 of 24