MAINTENANCE GUIDE
4.4 Fan
Tools
Remove the combustion assembly (see 4.3)
1
Legend:
1 - Fan
2 - Venturi
3 - Gasket
Fan & mixer venturi according to the model
Power
Fan
18 kW
EBM RG 118 40 W
24 kW
EBM RG 118 40 W
30 kW
EBM RG 118 40 W
38 kW
EBM RG 118 40 W
64
TIME
15 min
2
Venturi diameter
Ø 14
Ø 17
Ø 21
Ø 25
Remove the three screws to free the fan.
2
1
3