No.
Parameter
026 Non-Standard
027 Short Protocol B
028 Short Protocol D
029 Remote
Diagnostics
030 CED & 300 bps
031 RTC = EOL x 12
032 V34 TX Start
033 V34 RX Start
034 V34 TX SR
035 V34 RX SR
036 Not Used
037 Protocol Display
038 Not Used
039 Flash Time
040 Flash Time
(PSTN)
041 Pause Time
042 Not Used
043 Redial Interval
044 Redial Count
Ver. 1.2
Function Parameter Table
Selections
1 = Off (Invalid)
2 = On (Valid)
1 = Off (Invalid)
2 = On (Valid)
1 = Off (Invalid)
2 = On (Valid)
1 = Off (will not accept)
2 = On (accepts)
1 = 75 ms
2 = 1 sec
1 = Off (EOLx6)
2 = On (EOLx12)
2400-33600bps
2400-33600bps
2400-3429sr
2400-3429sr
1 = Off (not displayed)
2 = On (displayed)
5 = 50 ms
~
100 = 1000 ms
5 = 50 ms
~
100 = 1000 ms
1 = 1 sec.
~
10 = 10 sec.
0 = no waiting
~
15 = 15 minutes
0 = no redial
~
15 = 15 times
0 ~ 9 (For Australia Only)
Selects own mode (Panafax mode).
Selects the short protocol mode.
Selects the short protocol mode. When activated, it
allows the machine to automatically store the
modem speed for each Auto Dial Number.
Selects whether the machine accepts Remote
Diagnostics from the service station.
Selects the pause interval between the CED and
the 300 bps signal.
(Used when Echo Suppression is disabled.)
Selects the RTC signal, EOLx6 or EOLx12.
Selects the transmission modem start speed for
V.34 communication, 33600-2400 bps.
Press "V" or "/\ " to select the symbol rate.
Selects the receiving modem start speed for V.34
communication, 33600-2400 bps.
Press "V" or "/\ " to select the symbol rate.
Selects the transmission symbol rate for V.34, 3429/
3200/3000/2800/2400 sr.
Press "V" or "/\ " to select the symbol rate.
Selects receiving symbol rate for V.34, 3429/3200/
3000/2800/2400 sr.
Press "V" or "/\ " to select the symbol rate.
Selects whether to display the modem speed
during communication.
(Press the Job Status Key to display)
Selects the pause interval before activating the
Flash key.
Selects the pause interval before activating the
Flash key.
(For Germany, Austria and Czech)
Selects the pause interval from 1 sec. ~ 10 sec. for
dialing through a switchboard or for international
calls.
Selects the redial interval from 0 to 15 minutes in 1
minute steps.
Selects the redial count from 0 to 15 times in 1 step
intervals.
Note:
In order to comply with the requirements TBR21
in the EC countries, do not select 15 times.