Information Codes Table (For Facsimile) - Panasonic DP-1820P Service Manual

Hide thumbs Also See for DP-1820P:
Table of Contents

Advertisement

4.7.

Information Codes Table (For Facsimile)

Code
Mode
012
RCV
030
XMT
031
XMT
COPY
061
-
200
RCV
212
XMT
RCV
301
XMT
RCV
331
XMT
400
XMT
401
XMT
402
XMT
403
RCV
(Polling)
404
XMT
Ver. 1.2
Fax Information Codes
Phase
Description of Problem
C, D
The length of the received
document is over 2 m.
B
Read Point Sensor does not
activate within 4 seconds after the
document starts feeding.
C
Transmitting document was longer
than 2,000 mm (78.7 in).
(Super Fine: 1,000 mm (39.4 in),
600 dpi: 430 mm (16.2 in))
A
ADF Door is open.
C
Decoding process did not
complete at the end of phase C.
A-E
Interface error occurred between
the CPU and modem.
System fault.
C
8-minutes timer error.
(Germany only)
B
T1 timer (35±5 sec) elapsed
without detecting 300 bps signal.
B
DCN was returned from receiver
while transmitter is waiting for CFR
or FTT.
B
DCN was returned from receiver
while transmitter is waiting for
NSF/DIS.
B
Transmitter had no polling
function.
B
Transmitter sent NSS (or DCS)
followed by TCF three times, but
the receiver did not respond. (CFR
or FTT is usually returned)
Document not set properly.
Defective Read Point Sensor.
Document may be jammed.
Defective Read Point Sensor.
Cover not firmly closed.
Connectors not firmly connected.
Defective FXB PCB.
Modem defective. (FXB PCB)
Software problem occurred. (SC PCB)
Software problem occurred. (SC PCB)
Wrong number dialed and the START
button was pushed.
Telephone line disconnected while
dialing.
FXB PCB (Modem) or MJR PCB
defective.
Receiver defective. (It may only be
transmitting CED)
Your machine's ID Number is not
programmed.
Possible incompatibility or incorrect
Password (Password Reception,
Selective Receive).
Mailbox full.
Receiver working in non-CCITT mode
only. (Possible incompatibility)
"POLLED=ON" (polling XMT ready) not
set at the transmitter.
Document to be transmitted not placed
at the transmitter.
Receiver defective. (Modem, MJR PCB,
etc.)
FXB PCB or MJR PCB defective.
Receiver disconnects line during first
NSS (or DCS) transmitted.
164