Maintenance
GREASING BEARINGS AND
BUSHINGS (Fig. 22–30)
The machine has grease fittings that must be lubricated
regularly with No. 2 General Purpose Lithium Base
Grease. If the machine is operated under normal condi-
tions, lubricate all bearings and bushings after every 50
hours of operation or immediately after every washing.
1.
The grease fitting locations and quantities are:
Cutting unit carrier frame and pivot (2 ea.)
(Fig. 22); Rear axle tie rod (2), Steering cylinder
ball joints (2), (Fig. 23); Front lift cylinders (2),
(Fig. 24); Front lift cylinder (1), (Fig. 25); Rear lift
cylinder pivot (2), (Fig. 26); Lift arm pivot (3),
(Fig. 27); Rear axle pivot (Fig. 28) Rear lift arm
pivots (2) (Fig. 29) and Brake pedal shaft (1)
(Fig. 30).