ESAB A120 Operating Manual page 80

Automated plasma cutting system
Table of Contents

Advertisement

Material
Gas Pressure
Thickness
(mm)
1
2
3
4
5
6
8
10
12
15
20
BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.
0-5430
Arc Voltage
(Air)
Bar
(torch lead
Volts
length)
101
116
118
126
125
5.9 (7.6m)
127
6.2 (15.2m)
131
134
136
132
144
Torch
Working
Travel Speed
Height
(mm)
(mm/min)
3.3
4590
3.3
3925
3.3
3285
3.3
1985
3.3
1850
3.3
1605
3.3
1100
3.3
670
4.8
490
3.3
375
4.8
230
OPERATION
CUTMASTER A120
Initial
Kerf Width
Piercing
Pierce Delay
Height
(mm)
(sec)
5.1
0.00
5.1
0.10
5.1
0.10
5.1
0.20
5.1
0.20
5.1
0.30
5.1
0.40
5.1
0.50
6.4
0.90
Edge Start
Edge Start
@ Rec.
Speed
(mm)
1.2
1.7
1.7
2.2
2.1
2.1
2.1
2.1
2.2
2.6
2.5
4T-49