2.05 Input Wiring Specifications
Cutmaster A120 Power Supply Input Cable Wiring Requirements
Input
voltage
Volts
1 Phase
208
230
460
3 Phase
208
230
380
400
460
600
NOTE!
Refer to Local and National Codes or local authority having jurisdiction for proper wiring require-
ments.
The suggested sizes are based on flexible power cable with power plug installations. For hard-
wired installations refer to local or national codes.
I1max is taken at TDC rated minimum duty cycle.
I1eff is taken at TDC 100% rated duty cycle
0-5430
Freq
Power
Input
Hz
kVA
I max
60
26.2
126
60
27.6
118
60
35
76
60
21.6
60
60
22.3
56
50
23
35
50
23.6
34
60
29.5
37
60
29.0
28
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electric Code
I eff
Fuse
(amps)
98
150
95
125
68
100
55
60
50
60
32
40
31
40
33
40
25
30
INTRODUCTION
CUTMASTER A120
Suggested Sizes
Flexible Cord
Flexible Cord
(Min. AWG)
(Min. mm
4 Type W
25 Type W
4 Type W
25 Type W
4
4
4
8
8
8
10
)
2
25
25
25
10
10
10
6
2-3