Material
Gas Pressure
Thickness
(mm)
1
2
3
4
5
6
8
10
12
15
20
25
BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.
0-5430
Arc Voltage
(Air)
Bar
(torch lead
Volts
length)
109
111
113
110
111
5.9 (7.6m)
114
120
6.2 (15.2m)
125
123
130
143
152
Torch
Working
Travel Speed
Height
(mm)
(mm/min)
4.8
8915
4.8
7415
4.8
5915
4.8
4095
4.8
3325
4.8
2745
4.8
1775
4.8
1060
4.8
1025
4.8
610
6.4
395
6.4
210
OPERATION
CUTMASTER A120
Initial
Kerf Width
Piercing
Pierce Delay
Height
(mm)
(sec)
5.1
0.00
5.1
0.10
5.1
0.10
5.1
0.30
5.1
0.30
5.1
0.40
5.1
0.50
5.1
0.50
5.1
0.60
5.1
0.75
Edge Start
Edge Start
@ Rec.
Speed
(mm)
1.5
1.7
1.8
1.7
1.8
2.2
2.3
2.3
2.3
2.5
2.7
3.2