Material
Gas Pressure
Thickness
(mm)
1
2
3
4
5
6
8
10
12
15
20
25
BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.
0-5430
Arc Voltage
(Air)
Bar
(torch lead
Volts
length)
115
120
118
120
121
5.9 (7.6m)
122
123
6.2 (15.2m)
125
130
134
138
149
Torch
Working
Travel Speed
Height
(mm)
(mm/min)
4.8
7540
4.8
7015
4.8
4570
4.8
3650
4.8
2465
4.8
2145
4.8
1635
4.8
1180
4.8
795
4.8
530
4.8
325
4.8
165
OPERATION
CUTMASTER A120
Initial
Kerf Width
Piercing
Pierce Delay
Height
(mm)
(sec)
4.8
0
4.0
0.10
4.8
0.10
4.8
0.20
4.8
0.20
4.8
0.30
4.8
0.40
4.8
0.60
4.8
0.75
Edge Start
Edge Start
Edge Start
@ Rec.
Speed
(mm)
2.1
1.9
2.1
1.9
2.1
2.0
2.2
2.4
2.4
2.4
2.2
2.7
4T-15