Teledyne Linea GigE 2K User Manual page 51

Monochrome cmos line scan
Hide thumbs Also See for Linea GigE 2K:
Table of Contents

Advertisement

Counter 1 End
Counter 2 End
Counter Reset Input Line
Activation
Rising Edge
Falling Edge
Any Edge
Counter Duration
Counter Value
Counter Value At Reset
Counter Reset
Timer Selector
Timer 1
Timer 2
Timer Mode
Off
Active
Timer Status
Timer Idle
Timer Trigger Wait
Timer Delaying
Timer Active
Timer Completed
Timer Start Source
TimerReset Cmd
Acquisition Start
Acquisition End
Exposure Start
Exposure End
Readout Start
Readout End
Frame Start
Line 1
Line 2
Line 3
Line 4
Timer 1 End
Timer 2 End
Counter 1 End
Linea GigE Series Camera
Counter1End
Counter2End
counterResetLineActivation
RisingEdge
FallingEdge
AnyEdge
counterDuration
counterValue
counterValueAtReset
counterReset
timerSelector
Timer1
Timer2
timerMode
Active
timerStatus
TimerIdle
TimerTriggerWait
TimerDelaying
TimerActive
TimerCompleted
timerStartSource
AcquisitionStart
AcquisitionEnd
ExposureStart
ExposureEnd
ReadoutStart
ReadoutEnd
FrameStart
Line1
Line2
Line3
Line4
Timer1End
Timer2End
Counter1End
Reset on the reception of the Counter 1 end.
Reset on the reception of the Counter 2 end.
Specify the edge transition on the selected line that
will reset the selected counter.
Reset counter on rising edge of the selected signal.
Reset counter on falling edge of the selected signal.
Reset counter on the falling or rising edge of the
selected signal
Sets the duration (or number of events) before the
CounterEnd event is generated.
Read the current value of the selected counter.
(RO)
Reads the value of the selected counter when it was
reset by a trigger or by an explicit Counter Reset
command. (RO)
Resets the selected counter to zero. The counter
starts immediately after the reset. To temporarily
disable the counter, set the Counter Event Source
feature to Off. (WO)
Selects which timer to configure.
Configure Timer 1
Configure Timer 2
Select the timer mode. The selected Timer is Active
or Disabled. When Disabled, the Timer can be
configured.
Off
The selected Timer is Disabled.
The selected Timer is Enabled.
Returns the current state of the timer. (RO)
The timer is idle. The CounterStartSource feature is
set to off.
The timer is waiting for a start trigger.
The timer is counting the requested delay.
The timer is counting for the specified duration.
The timer reached the TimerDuration count.
Select the trigger source to start the timer. The
Event Control section provides details and timing
diagrams for the supported events.
Off
Starts with the reception of the TimerReset
Icommand.
Start Timer on Acquisition Start event.
Start Timer on Acquisition End event.
Start Timer on Exposure Start event.
Start Timer on Exposure End event.
Start Timer on Readout Start event.
Start Timer on Readout End event.
Start Timer on Frame Start event.
Start Timer on a transition of I/O Line 1 event.
See Input Signals Electrical Specifications.
Start Timer on a transition of I/O Line 2 event.
Start Timer on a transition of I/O Line 3 event.
Start Timer on a transition of I/O Line 4 event.
Start Timer on Timer 1 End event.
Start Timer on Timer 2 End event.
Start Timer on Counter 1 End event.
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
Operational Reference • 49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Linea gige 4kLinea gige 8k

Table of Contents