Teledyne Linea GigE 2K User Manual page 49

Monochrome cmos line scan
Hide thumbs Also See for Linea GigE 2K:
Table of Contents

Advertisement

Display Name
Counter Selector
Counter 1
Counter 2
Counter mode
Off
Active
Counter Status
Counter Idle
Counter Trigger Wait
Counter Active
Counter Completed
Counter Overflow
Counter Start Source
Off
Acquisition Start
Acquisition End
Exposure Start
Exposure End
Readout Start
Readout End
Frame Start
Line 1
Line 2
Line 3
Line 4
Timer 1 End
Timer 2 End
Counter 1 End
Counter 2 End
Counter Start Line
Activation
Rising Edge
Falling Edge
Any Edge
Linea GigE Series Camera
Feature & Values
counterSelector
Counter1
Counter2
counterMode
Active
counterStatus
CounterIdle
CounterTriggerWait
CounterActive
CounterCompleted
CounterOverflow
counterStartSource
AcquisitionStart
AcquisitionEnd
ExposureStart
ExposureEnd
ReadoutStart
ReadoutEnd
FrameStart
Line1
Line2
Line3
Line4
Timer1End
Timer2End
Counter1End
Counter2End
counterStartLineActivation
RisingEdge
FallingEdge
AnyEdge
Description
Selects the counter to configure.
Select counter 1
Select counter 2
Selects the counter mode. The selected Counter is
either Active or Disabled. When Disabled, the
Counter can be configured.
Off
The selected Counter is Disabled
The selected Counter is Enabled
Returns the current state of the counter. (RO)
The counter is idle.
The CounterStartSource feature is set to off.
The counter is waiting for a start trigger.
The counter is counting for the specified duration.
The counter reached the CounterDuration count.
The counter reached its maximum possible count.
Select the counter start source. Counter increments
from 0 to the value of the counterDuration feature.
Off
Counter is stopped.
Counter starts on the reception of the Acquisition
Start event.
Counter starts on the reception of the Acquisition
End event.
Counter starts on the reception of the Exposure
Start event
Counter starts on the reception of the Exposure
End event.
Counter starts on the reception of the Readout
Start event.
Counter starts on the reception of the Readout End
event.
Counter starts on the reception of the Frame Start
event.
Counter starts on the specified transitions on Line 1
See Input Signals Electrical Specifications.
Counter starts on the specified transitions on Line 2
Counter starts on the specified transitions on Line 3
Counter starts on the specified transitions on Line 4
Counter starts on the reception of the Timer 1 End
event.
Counter starts on the reception of the Timer 2 End
event.
Counter starts on the reception of the Counter 1
End event.
Counter starts on the reception of the Counter 2
End event.
Selects the activation mode of the input line trigger
which starts the counter. This is only applicable
when the counterStartSource feature selects a
physical Line.
Starts counting on rising edge of the selected Line.
Starts counting on falling edge of the selected Line.
Starts counting on the falling or rising edge of the
selected Line.
Device Version
& View
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.10
Expert
DFNC
1.00
Expert
DFNC
Operational Reference • 47

Advertisement

Table of Contents
loading

This manual is also suitable for:

Linea gige 4kLinea gige 8k

Table of Contents