Counter Incremental
Source
Off
Acquisition Start
Acquisition End
Exposure Start
Exposure End
Readout Start
Readout End
Frame Start
Line 1
Line 2
Line 3
Line 4
Rotary Encoder
Internal Clock
Timer 1 End
Timer 2 End
Counter Incremental Line
Activation
Rising Edge
Falling Edge
Any Edge
Counter Reset Source
Reset Cmd
Acquisition Start
Acquisition End
Exposure Start
Exposure End
Readout Start
Readout End
Frame Trigger
Line 1
Line 2
Line 3
Line 4
Timer 1 End
Timer 2 End
48 • Operational Reference
counterIncrementalSource
AcquisitionStart
AcquisitionEnd
ExposureStart
ExposureEnd
ReadoutStart
ReadoutEnd
FrameStart
Line1
Line2
Line3
Line4
rotaryEncoder1
InternalClock
Timer1End
Timer2End
counterIncrementalLineActivation
RisingEdge
FallingEdge
AnyEdge
counterResetSource
AcquisitionStart
AcquisitionEnd
ExposureStart
ExposureEnd
ReadoutStart
ReadoutEnd
FrameStart
Line1
Line2
Line3
Line4
Timer1End
Timer2End
Select the event source which increments the
counter. The Event Control section provides details
and timing diagrams for the supported events.
Off
Counter is stopped.
Counts the number of Acquisition Start events.
Counts the number of Acquisition End events.
Counts the number of Exposure Start events.
Counts the number of Exposure End events.
Counts the number of Readout Start events.
Counts the number of Readout End events.
Counts the number of Frame Start events.
Counts the number of transitions on Line 1 (based
on the counterIncrementalLineActivation feature
setting)
See Input Signals Electrical Specifications.
Counts the number of transitions on Line 2 (based
on the counterIncrementalLineActivation feature
setting)
Counts the number of transitions on Line 3 (based
on the counterIncrementalLineActivation feature
setting)
Counts the number of transitions on Line 4 (based
on the counterIncrementalLineActivation feature
setting)
The counter increments on rotary encoder ticks.
The counter increments on each microsecond tick
of the device internal Clock.
Counts the number of Timer 1 End events.
Counts the number of Timer 2 End events.
Selects the counter signal activation mode for line
inputs. The counter increments on the specified
signal edge or level.
Increment the counter on the rising edge of the
selected I/O Line.
Increment the counter on the falling edge of the
selected I/O Line.
Increment the counter on the falling or rising edge
of the selected I/O Line.
Selects the signal source to reset the counter then
waits for the next countStartSource signal or event.
Off
Reset on reception of the Reset Icommand.
Reset on reception of the Acquisition Start.
Reset on reception of the Acquisition End.
Reset on reception of the Exposure Start event.
Reset on reception of the Exposure End event.
Reset the counter on the reception of the Readout
Start event.
Reset the counter on the reception of the Readout
End event.
Reset on reception of the Frame Trigger.
Reset counter on the specified transition on line 1.
See Input Signals Electrical Specifications.
Reset counter on the specified transition on line 2.
Reset counter on the specified transition on line 3.
Reset counter on the specified transition on line 4.
Reset on reception of the Timer 1 End.
Reset on reception of the Timer 2 End.
1.00
Expert
DFNC
1.00
Expert
DFNC
1.10
Expert
DFNC