Rotary Encoder Rescaler
Order
Multiplier Divider
Divider Multiplier
Rotary Encoder Multiplier
Rotary Encoder Divider
Rotary Encoder Direction
Clockwise
Counter Clockwise
Rotary Encoder Input A
Source
Line 1
Line 3
Rotary Encoder Input B
Source
GND
Line 2
Line 4
Rotary Encoder Source
Activation
Rising Edge
Any Edge
Rotary Encoder Multiplier
Rotary Encoder Divider
Line Selector
Line 1
Line 2
Line 3
Line 4
Line 5
Line 6
Line Format
SingleEnded
Open Collector
RS422
38 • Operational Reference
rotaryEncoderRescalerOrder
multiplierDivider
dividerMultiplier
rotaryEncoderMultiplier
rotaryEncoderDivider
rotaryEncoderDirection
Clockwise
CounterClockwise
rotaryEncoderInputASource
Line1
Line3
rotaryEncoderInputBSource
GND
Line2
Line4
rotaryEncoderSrcActivation
RisingEdge
AnyEdge
rotaryEncoderMultiplier
rotaryEncoderDivider
LineSelector
Line1
Line2
Line3
Line4
Line5
Line6
LineFormat
SingleEnded
OpenCollector
RS422
Specifies the order that the multiplier and divider
are applied.
The signal is multiplied before been divided.
The signal is divided before been multiplied.
Specifies a multiplication factor for the rotary
encoder output pulse generator.
Specifies a division factor for the rotary encoder
output pulse generator.
Specifies the phase which defines the encoder
forward direction.
Inspection goes forward when the rotary encoder
direction is clockwise (phase B is ahead of
phase A).
Inspection goes forward when the rotary encoder
direction is counter clockwise (phase A is ahead of
phase B).
Selects which input line to assign to the rotary
encoder input A (also known as shaft encoder).
Note that the Line Mode feature must be set to
Input. The list of supported input line sources is
device-specific.
Line1 is assigned to the Rotary Encoder Input A
Line3 is assigned to the Rotary Encoder Input A
Selects which input line to assign to the rotary
encoder input B (also known as shaft encoder).
Note that the Line Mode feature must be set to
Input. The list of supported input line sources is
device-specific.
Rotary Encoder Input B is not used
Line2 is assigned to the Rotary Encoder Input B
Line4 is assigned to the Rotary Encoder Input B
Specifies the signal edge(s) use to increment the
rotary encoder.
The rotary encoder uses the rising edge of the
source signal.
The rotary encoder uses either the rising edge or
falling edge of the source signal.
Specifies a multiplication factor for the rotary
encoder output pulse generator.
Specifies a division factor for the rotary encoder
output pulse generator.
Selects the physical line (or pin) of the external
device connector to configure.
Index of the physical line and associated I/O
control block to use.
Specify the current electrical format of the
selected physical input or output. Applies to all
physical lines. (RO)
The line is single ended input for
3.3V/5V/12V/24V or output for 3.3V LVTTL
The line is output as open collector.
The line accepts or sends RS422 level signals.
1.00
Guru
DFNC
1.00
DFNC
Beginner
1.00
DFNC
Beginner
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Beginner
1.00
Expert
Linea GigE Series Camera

Advertisement

Table of Contents
loading

This manual is also suitable for:

Linea gige 4kLinea gige 8k

Table of Contents