Ecologic Control System Operation And Indications - Vermont Castings 33CFDVNV Installation And Operating Instructions Manual

Cfdv series direct vent gas fireplace
Table of Contents

Advertisement

CFDV Series Gas Fireplace
46
OPERATIONS AND INDICATIONS
CONTROL
BOARD
System Set Up Chart
NOTE: When using ON/OFF wall switch, the master switch, located in bottom of fireplace must be in the
ON position to perform all configuration setup operations.
FUNCTION
OPERATION
Cold Climate Pilot On/Off
Flip the toggle switch to ON.
Operations
FUNCTION
OPERATION
Power Up
Flip the Master Switch to ON position to power up the system.
Turn on wall switch to turn the fireplace on. NOTE: If master switch was
Fireplace On
just switched to ON, then at first use of wall switch, it may need to be
turned ON - OFF - ON to synchronize the two switch settings.
Turn the wall switch to the OFF position, or turn the ON/OFF master
Fireplace Off
switch to the OFF position
Self Diagnostics Chart
The fireplace has a self diagnostic LED on the control board enabling you to troubleshoot problems and
potentially avoid a service call. Please refer to the chart below for indicator reference.
FUNCTION
OPERATION
Sparking error
Red LED, Flash 2 times
Flame error
Red LED, Flash 3 times
Ignition fail
Red LED, Flash 4 times
Re-ignite warning
Red LED, Flash 5 times
Pilot valve voltage error
Red LED, Flash 6 times
Main valve voltage error
Red LED, Flash 7 times
Low battery
Red LED 2.5 sec, Flash once
Remote Operations
The following functions are available on the RMSC hand held remote.
NOTE: Flame height control is only available with purchase and installation of a stepper motor kit with RF
receiver
REMOTE FUNCTION
OPERATION
Fireplace On
Press the ON button on the transmitter.
Press the OFF button 3 times or hold the OFF button 3
Fireplace Off
seconds for memory off.
Press the ON button once to turn on the fireplace with
Flame Height Up
maximum flame setting.
Press the OFF button to lower the flame height to
Flame Height Down
medium and low.
Press TIMER button to enter the timer mode. Keep
Count Down Timer Mode
pressing the TIMER button to set the desired time or
press TIMER button to "0" to exit timer mode.
OPERATING INSTRUCTIONS – IPI
®
2.0
Cold
Climate
Switch
Master
Switch
ICON
DEFAULT
SETTING
OFF
20306739