All Control/Pilot Systems; Optional Accessories - Vermont Castings 33CFDVNV Installation And Operating Instructions Manual

Cfdv series direct vent gas fireplace
Table of Contents

Advertisement

OPTIONAL ACCESSORIES

ALL PILOT/CONTROL SYSTEMS
SYMPTOM
The pilot and main burner
extinguish while in operation
Glass soots
Flame burns blue and lifts off
burner (ghosting)
OPTIONAL ACCESSORIES
There are a variety optional accessories available for
the CFDV Direct Vent Fireplace. Porcelain panels are
available as an alternative to the firebrick provided with
your fireplace. The porcelain panels can give your fireplace
a smooth contemporary look and feel.
The Contemporary Stone and Glass Kit includes a set
of ceramic fiber stones and fireglass and can be used
to alter your fireplace from a rustic look to a minimalist
appearance. Additional crushed fireglass is available in a
variety of colors.
There is also a choice of two optional fans. The BLOT fan
utilizes a thermostat for blower operation. The FK12 fan
is also available. A speed control is available to regulate
fan speed.
Porcelain Panel Kit (33CFDV)
Porcelain Panel Kit (36CFDV)
Porcelain Panel Kit (42CFDV)
Contemporary Stone and Glass Kit
20306739
POSSIBLE CAUSE
Inner vent pipe leaiking exhaust
gasses back into system
Horizontal vent improperly pitched.
Improper vent cap intallation
Flame impingement on logs
Insufficient fresh air being supplied
PL33CFDVB
PL36CFDVB
PL42CFDVB
CKCFDV
ACTION
Check for product leak. Replace defective
pipe section.
Check that horizontal venting pipe is
running upward
pipe level or downward.
Check for proper installation and that cap
is clear of debris or blockage.
Install log set per the instructions. Inspect
the injector and air intake area. Make sure
this area does not have any blockage from
debris and clean. Check gas supply.
Check:
1. That the vent cap is installed properly
and free of debris.
2. That the vent system joints are tight and
have no leaks.
3. That no debris is blocking the inner
air intake at the bottom back of the
combustion chamber.
4. That the glass is properly secured and
latched.
Crushed Fireglass Kits:
Glass Kit Bronze
Glass Kit Diamond
Glass Kit Onyx
Glass Kit Sapphire
Blower Kits:
T-Stat Blower w/ Speed Control
Manual Blower
Speed Control for FK12
CFDV Series Gas Fireplace
" per foot. Do not run the
1
4
GKB
GKD
GKO
GKS
BLOT
FK12
26D0746
57

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents