JUNCTION BOX WIRING

1. This should be done before framing the fireplace. Wire
the receptacle into an electrical circuit. Wire with mini-
mum 60° C wire in accordance with prevailing codes.
2. Remove the external junction box cover by removing
the screw from the side of the outside firebox wall.
Junction box was installed at the factory.
3. The junction box cover has a factory installed "romex"
style strain relief connector. After connecting the wires,
route the wire leads through this connector. Refer to
the wiring diagram in Figure 75.
Junction Box
Figure 75 –
Junction Box Wiring Diagram
FP1912
Junction box wiring
8/08
42
120V AC
60Hz
Factory Supplied
Not Supplied
ELECTRICAL INSTALLATION – IPI

WALL SWITCH INSTALLATION

The wall switch wire connection is located off the wire
harness coming out of the IPI Control Board. The wire is
labeled 'wall switch'. Connect the low voltage switch wires
to the two (2) terminals labeled "wall switch" from the control
board. Run wire to desired location on wall. Up to 50 feet
of 18 gauge wire may be used if necessary. Attach wires
to wall switch. Mount the wall switch in a junction box and
screw on cover. Figure 76
WARNING
Do NOT connect wall switch to 110V circuit.
20306739