Table 143 SNMP System Traps (continued)
OPTION
OBJECT LABEL
voltage
VoltageEventOn
VoltageEventClear
reset
UncontrolledResetEventO
n
ControlledResetEventOn
RebootEvent
timesync
RTCNotUpdatedEventOn
RTCNotUpdatedEventClea
r
intrusionlock
IntrusionLockEventOn
loopguard
LoopguardEventOn
errdisable
errdisableDetectTrap
errdisableRecoveryTrap
Chapter 40 Access Control
OBJECT ID
1.3.6.1.4.1.890.1.5.8.68.27.2.1
1.3.6.1.4.1.890.1.5.8.57.27.2.1
1.3.6.1.4.1.890.1.5.8.80.27.2.1
1.3.6.1.4.1.890.1.5.8.68.27.2.2
1.3.6.1.4.1.890.1.5.8.57.27.2.2
1.3.6.1.4.1.890.1.5.8.80.27.2.2
1.3.6.1.4.1.890.1.5.8.68.27.2.1
1.3.6.1.4.1.890.1.5.8.57.27.2.1
1.3.6.1.4.1.890.1.5.8.80.27.2.1
1.3.6.1.4.1.890.1.5.8.68.27.2.1
1.3.6.1.4.1.890.1.5.8.57.27.2.1
1.3.6.1.4.1.890.1.5.8.80.27.2.1
1.3.6.1.4.1.890.1.5.0.1
1.3.6.1.4.1.890.1.5.8.68.27.2.1
1.3.6.1.4.1.890.1.5.8.57.27.2.1
1.3.6.1.4.1.890.1.5.8.80.27.2.1
1.3.6.1.4.1.890.1.5.8.68.27.2.2
1.3.6.1.4.1.890.1.5.8.57.27.2.2
1.3.6.1.4.1.890.1.5.8.80.27.2.2
1.3.6.1.4.1.890.1.5.8.68.27.2.1
1.3.6.1.4.1.890.1.5.8.57.27.2.1
1.3.6.1.4.1.890.1.5.8.80.27.2.1
1.3.6.1.4.1.890.1.5.8.68.27.2.2
1.3.6.1.4.1.890.1.5.8.57.27.2.2
1.3.6.1.4.1.890.1.5.8.80.27.2.2
1.3.6.1.4.1.890.1.5.8.68.130.4.1
1.3.6.1.4.1.890.1.5.8.57.130.4.1
1.3.6.1.4.1.890.1.5.8.80.130.4.1
1.3.6.1.4.1.890.1.5.8.68.130.4.2
1.3.6.1.4.1.890.1.5.8.57.130.4.2
1.3.6.1.4.1.890.1.5.8.80.130.4.2
MES3500 Series User's Guide
306
DESCRIPTION
This trap is sent when the voltage goes
above or below the normal operating range.
This trap is sent when the voltage returns to
the normal operating range.
This trap is sent when the Switch
automatically resets.
This trap is sent when the Switch resets by
an administrator through a management
interface.
This trap is sent when the Switch reboots by
an administrator through a management
interface.
This trap is sent when the Switch fails to get
the time and date from a time server.
This trap is sent when the Switch gets the
time and date from a time server.
This trap is sent when intrusion lock occurs
on a port.
This trap is sent when loopguard shuts down
a port.
This trap is sent when an error is detected
on a port, such as a loop occurs or the rate
limit for specific control packets is
exceeded.
This trap is sent when the Switch ceases the
action taken on a port, such as shutting
down the port or discarding packets on the
port, after the specified recovery interval.