ZyXEL Communications MES3500 series User Manual page 299

Layer 2 management switch
Hide thumbs Also See for MES3500 series:
Table of Contents

Advertisement

Figure 193 Management > Maintenance > Tech-Support
You may need WordPad or similar software to see the log report correctly. The table below describes
the fields in the above screen.
Table 139 Management > Maintenance > Tech-Support
LABEL
DESCRIPTION
CPU Loading
Type a number ranging from 50 to 100 in the CPU threshold box, and type another
number ranging from 5 to 60 in the seconds box then click Apply.
For example, 80 for CPU threshold and 5 for seconds means a log will be created
when CPU utilization reaches over 80% and lasts for 5 seconds.
The log report holds 7 days of CPU log data and is stored in volatile memory (RAM).
The data is lost if the Switch is turned off or in event of power outage. After 7 days,
the logs wrap around and new ones and replace the earliest ones.
The higher the CPU threshold number, the fewer logs will be created, and the less
data technical support will have to analyze and vice versa.
Mbuf Usage
Type a number ranging from 50 to 100 in the Mbuf (Memory Buffer) threshold box.
The Mbuf log report is stored in flash (permanent) memory.
For example, Mbuf 50 means a log will be created when the Mbuf utilization is over
50%.
The higher the Mbuf threshold number, the fewer logs will be created, and the less
data technical support will have to analyze and vice versa.
Apply
Click Apply to save your changes to the Switch's run-time memory. The Switch loses
these changes if it is turned off or loses power, so use the Save link on the top
navigation panel to save your changes to the non-volatile memory when you are
done configuring.
Cancel
Click Cancel to begin configuring this screen afresh.
All
Click Download to see all the log report and system status. This log report is stored
in flash memory. If the All log report is too large, you can download the log reports
separately below.
Crash Dump
Click Download to see the crash log report. The log will include information of the
last crash and is stored in flash memory.
CPU Loading History
Click Download to see the CPU loading history log report. The 7-days log is stored in
RAM and you will need to save it, otherwise it will be lost when the Switch is
shutdown or during power outage.
Memory Usage
Click Download to see the memory usage log report. This log report is stored in
flash memory.
Chapter 39 Maintenance
MES3500 Series User's Guide
299

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents